BeeLINK2 connections.

The IR/ sense socket is output for the IR-emitter that sends IR to the device to be operated. In some cases this socket is also used for sensing purposes. Often the BeeLINK2 controller needs to know if the device is powered up or not. In some cases this socket is used for other serial communication like RS-232.

Prog switch is a push button that must be activated to initiate a programming sequence, as described in the option programming chapters.

Do not use socket is for firmware updating of the controller. If used for anything else, the controller can be damaged.

LED indicates different operating modes:

Red-green flash: No data has been received since power has been applied

Red flash:

The controller is in option programming mode.

Red:

The controller is active.

Green:

The controller is inactive.

 

 

A BeeLINK2 controller connects to the BeeBUS via a RJ45 connector and CAT5 cable.

Warning:

If connected to a computer network, this is likely to be damaged. Connect only to a BeeLINK bus.

Page 7
Image 7
Sony 6124 manual BeeLINK2 connections