CDX-GT21W/GT210/GT260/GT260S

SECTION 3

DIAGNOSIS FUNCTION

Description of the Diagnostics function:

1.Setting the Diag display mode

With the power off, press the [4] button, [5]button, and [4] button on the set body or the remote control (for more than 2 seconds) in turn.

4.Contents of each display mode

4-1. Reset count display mode

01 XX

Reset count

(in hexadecimal format)

2.Canceling the Diag display mode

During the Diag function mode, press the [OFF] button.

3.Initial display in the Diag display mode.

Just when the Diag mode is entered, “reset count” is displayed. The display mode is switched by each rotation of

M >/SEEK + or . m/SEEK – keys.

Reset count display

01 XX

Reset count by watchdog timer display

02 XX

Number of connected units display

031 XXX

Operating hours display

Diag code

01: Reset count

4-2. Reset count by watchdog timer display mode

02 XX

Reset count

(in hexadecimal format)

Diag code

02: Number of resets by watchdog timer

4-3. Number of connected units display mode

031 XXX

Show the number of connected units for CD-C, MD-C and XM respectively from the rightmost (in hexadecimal format).

Recency of information

1-3: 1 represents the latest.

Diag code

03: Number of connected unit.

04 XXXX

CD error information display

051 XX

OFFSET/FAILURE error display

061XXXXX

The display mode is switched by each rotation of [2] or [1] keys during the number of connected units display mode.

No. of connected units history 1 (latest) display

031 XXX

No. of connected units history 2 display

032 XXX

No. of connected units history 3 display

033 XXX

4-4. Operating hours display mode

04 XXXX

Operating hours

(in hexadecimal format)

Diag code

04: Operating hours

16

Page 16
Image 16
Sony CDX-GT21W, CDX-GT210 Section Diagnosis Function, Reset count display mode, Reset count by watchdog timer display mode