1. SERVICE NOTE

ENGLISH

1-1. POWER SUPPLY DURING REPAIRS

In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so that the unit cannot operate.

These following method is available to prevent this.

Method:

Use the AC power adaptor (AC-L200/L200B).

1-2. SELF-DIAGNOSIS FUNCTION

1-2-1. Self-diagnosis Function

When problems occur while the unit is operating, the self-diagnosis function starts working, and displays on the Viewfinder or the LCD screen what to do. This function consists of two display; self- diagnosis display and service mode display.

Details of the self-diagnosis functions are provided in the Instruction manual.

Viewfinder or LCD screen

C : 3 1 : 1 1

Blinks at 3.2Hz

1-2-2. Self-diagnosis Display

When problems occur while the unit is operating, the counter of the Viewfinder or the LCD screen shows a 4-digit display consisting of an alphabet and numbers, which blinks at 3.2 Hz. This 5-character display indicates the “repaired by:”, “block” in which the problem occurred, and “detailed code” of the problem.

C 3 1 1 1

Repaired by:

C : Corrected by customer

H : Corrected by dealer

E : Corrected by service engineer

 

 

Block

 

 

Detailed Code

 

 

 

 

 

 

 

Indicates the appropriate

Refer to “1-2-3. Self-diagnosis Code Table”.

step to be taken.

 

 

 

E.g.

 

 

 

31

....Reload the tape.

 

 

 

32

....Turn on power again.

 

 

 

HDR-SR11/SR11E/SR12/SR12E_L2