ENGLISH

JAPANESE

1-2-3. Self-diagnosis Code Table

 

Self-diagnosis Code

 

 

 

by:

 

Block

Detailed

Symptom/State

Correction

Repaired

 

 

Function

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

0

4

0

0

Non-standard battery is used.

Use the InfoLITHIUM battery.

 

 

 

 

 

 

 

 

C

 

1

3

0

1

“Memory Stick Duo” is unformatted.

Format the “Memory Stick Duo”.

 

“Memory Stick Duo” is broken.

Insert a new “Memory Stick Duo”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

1

3

0

2

Disc access error

Remove the power source. Reconnect it again and operate your

 

camcorder again

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Retry turn the power on by the power switch. If it does not

C

 

3

2

6

0

Difficult to adjust focus

recover, check the focus MR sensor of lens block (pin w;, wa of

 

(Cannot initialize focus)

CN5103 on the LD-230 board). If it is OK, check the focus

 

 

 

 

 

 

 

 

 

 

 

 

 

motor drive IC (IC5201 on the LD-230 board).

 

 

 

 

 

 

 

 

E

 

2

0

0

0

Flash memory data are rewritten.

Make flash memory data correct value. (Note 1)

 

 

 

 

 

 

 

 

E

 

3

1

0

0

Drive fault

Inspect or replacement of the hard disk drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect the lens block zoom MR sensor (pin qh, qj of CN5103

E

 

6

1

1

0

Zoom operations fault

on the LD-230 board) when zooming is performed when the

 

(Cannot initialize zoom lens.)

zoom lever is operated, and the zoom motor drive circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

(IC5201 on the LD-230 board) when zooming is not performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The abnormalities in initialization of

 

E

 

6

1

1

1

the focus lens and the abnormalities in

Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.

 

initialization of the zoom lens occurred

 

 

 

 

 

 

 

 

 

 

 

 

 

simultaneously.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Handshake correction function does not

Inspect PITCH angular velocity sensors (SE9001 on the FR-278

E

 

6

2

0

0

work well. (With PITCH angular

 

board) peripheral circuits.

 

 

 

 

 

 

velocity sensor output stopped.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Handshake correction function does not

Inspect YAW angular velocity sensors (SE9002 on the FR-278

E

 

6

2

0

1

work well. (With YAW angular velocity

 

 

 

 

 

 

sensor output stopped.)

board) peripheral circuits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

6

2

0

2

Abnormality of IC for steadyshot.

Refer to [1-3-1. E : 62 : 02 (Abnormality of IC for Steadyshot)

 

Occurred].

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

6

2

0

3

IC for steadyshot and micro controller

Inspect the steadyshot circuit (IC5501 on the LD-230 board).

 

communication abnormality among.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

6

2

1

0

Shift lens initializing failure.

Replacement of lens block. If an error occurs again, replace the

 

LD-230 board. (Note 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

6

2

1

1

Shift lens overheating (Pitch)

Refer to [1-3-2. E : 62 : 11 (Shift Lens Overheating (Pitch))

 

 

Occurred].

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

6

2

1

2

Shift lens overheating (Yaw)

Refer to [1-3-3. E : 62 : 12 (Shift Lens Overheating (Yaw))

 

 

Occurred].

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

6

2

2

0

Abnormality of thermistor.

Refer to [1-3-4. E : 62 : 20 (Abnormality of Thermistor)

 

Occurred].

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

9

1

0

1

Abnormality when flash is being charged.

Checking of flash unit or replacement of flash unit.

 

 

 

 

 

 

 

 

E

 

9

4

0

0

Fault of writing or erasing the

Inspect the flash memory (IC2101 on the VC-516 board).

 

flash memory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1 : Refer to Service Manual, ADJ (“1-3. DESTINATION DATA WRITE”).

Note 2 : When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.

After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.

HDR-SR11/SR11E/SR12/SR12E_L2

1-2

Page 9
Image 9
Sony HDR-SR11E, HDR-SR12E service manual Self-diagnosis Code Table, Function Code