2 Press V/v repeatedly to selectthe item. Then, press .
Item

Explanation

RETRYPerforms the Auto

 

Calibration again.

 

 

SAVE

Saves the measurement

 

results and exits the setting

 

process.

 

 

WARN CHKDisplays warning

 

concerning the

 

measurement results. See

 

“When you select “WARN

 

CHK”” (page 28).

 

 

PHASE

Displays the phase of each

 

speaker (in phase/out of

 

phase). See “When you

 

select “PHASE”” (page 29).

 

 

DISTANCE

Displays the measurement

 

result for speaker distance.

 

 

LEVEL

Displays the measurement

 

result for speaker level.

 

 

EXITExits the setting process

 

without saving the

 

measurement results.
3 Save the measurement result.Select “SAVE” in step 2.The measurement results are saved.

When error codes appear

Try the remedies and perform the Auto Calibration again.Error code Cause and remedies

ERROR 32 None of the speakers were detected. Make sure that the optimizer microphone is connected properly and perform the Auto Calibration again.

If the optimizer microphone is connected properly but the error code appears, the optimizer microphone cable may be damaged or improperly connected.

ERROR F 33 • None of the front speakers are connected or only one front speaker is connected.

The optimizer microphone is not connected.

Error code Cause and remedies

ERROR SR 33 Either the left or right surround speakers is not connected.

ERROR SW 33 Sub woofer is not connected. Connect the sub woofer to the SUBWOOFER terminal.

ERROR 33 Wrong speaker detection due to noise. Make sure the environment is quiet during Auto Calibration.

To rectify the error

1Record down the error code.2Press , “RETRY Y” appears on the display.3Rectify the error.For details, see “When error codes appear” above.4Press to perform Auto Calibration again.

When you select “WARN CHK”

If a warning on the measurement result is present, detailed information is displayed.

Press to return to step 2 of “Confirming/saving the measurement results”.Warning code Explanation

WARN 40 The Auto Calibration has completed. However, the noise level is high. You may be able to perform the Auto Calibration properly if you try it again, even though the measurement cannot be performed in all environments. Try to perform the Auto Calibration in a quiet environment.

WARN 41 The sound input from the optimizer microphone is out of the acceptable range. It is louder than the loudest sound that can be measured. Try to perform the Auto Calibration when the environment is quiet enough to allow proper measurement.

WARN 42 The volume of the receiver is out of the acceptable range. Try to perform the Auto Calibration when the environment is quiet enough to allow proper measurement.

28GB