(1)Power ON, current probe method: 57 A (230V)
(2)Hot switching inrush current, measured in
accordance with European standard
(1)Power ON, current probe method: 55 A (230V)
(2)Hot switching inrush current, measured in
accordance with European standard
(1)Power ON, current probe method: 53 A (230V)
(2)Hot switching inrush current, measured in
accordance with European standard
Operating conditions
Temperature: 0 to 35°C (32 to 95°F)
Humidity: 30 to 85 % (No condensation)
Pressure: 700 to 1,060 hPa
Transport and storage conditions Temperature:
104°F) Humidity: 0 to 90 % Pressure: 700 to 1,060 hPa
Dimensions (w/h/d)
mm(19 ⋅ 51/4 ⋅ 17/8 inches)
mm (19 ⋅ 51/4 ⋅ 17/8 inches)
mm (19 ⋅ 31/2 ⋅ 17/8 inches)
Mass
AC adaptor (1)
AC adaptor holder (1)
Screws for AC adaptor holder (2) AC cord (1)
Warranty Card (1) Operating Instructions (1)
Optional accessory
Input adaptor
Design and specifications are subject to change without notice