12.FOCUS BIAS ADJUSTMENT

8.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob so that the waveform of the oscilloscope becomes the specified value.

(When the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob is turned, the – 28 –Manual background of “EFB-

Manual backgroundManual background ” changes and the waveform changes.) In this adjustment, waveform varies at intervals of approx. 2%. Adjust the wave- form so that the specified value is satisfied as much as pos- sible.

(Write power traverse adjustment)

(Traverse Waveform)

A

VC

B

Specification A = B

9.Press the [YES] button, and save the adjustment results in the

non-volatile memory. (“EFB = Manual backgroundManual background SAV” will be displayed for a moment.)

10.“EFB = Manual backgroundManual background MO-P”. will be displayed.

The optical pick-up moves to the pit area automatically and servo is imposed.

11.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob until the waveform of the os- cilloscope moves closer to the specified value.

In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.

(Traverse Waveform)

A

VC

B

Specification A = B

12.Press the [YES] button, and save the adjustment results in the

non-volatile memory. (“EFB = Manual backgroundManual background SAV” will be displayed for a moment.)

Next “EF MO ADJUS” is displayed. The disc stops rotating automatically.

13.Press the [ÊÊÊÊÊEJECT]¤ button and take out the disc.

14.Load the check disc (MD) TDYS-1.

15.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob and display “EF CD ADJUS” (C12).

16.Press the [YES] button and display “EFB = Manual backgroundManual background CD”. Servo is imposed automatically.

17.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob so that the waveform of the oscilloscope moves closer to the specified value.

In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.

(Traverse Waveform)

A

VC

B

Specification A = B

18.Press the [YES] button, display “EFB = Manual backgroundManual background SAV” for a mo- ment and save the adjustment results in the non-volatile memory.

Next “EF CD ADJUS” will be displayed.

19.Press the [ÊÊÊÊÊEJECT]¤ button and take out the disc.

12.FOCUS BIAS ADJUSTMENT

Adjusting Procedure :

1.Load the continuously-recorded disc. (Refer to “5. CREAT-

ING CONTINUOUSLY-RECORDED DISC”)

2.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob and display “CPLAY MODE” (C29).

3.Press the [YES] button and display “CPLAY MID”.

4. Press the [MENU/NO] button when “C =

AD = ” is

displayed.

 

5.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob and display “FBIAS ADJUS” (C13).

6.Press the [YES] button and display “ Manual backgroundManual backgroundManual backgroundManual background /Manual backgroundManual background a = Manual backgroundManual background ”.

The first four digits indicate the C1 error rate, the two digits after [/] indicate ADER, and the 2 digits after [a =] indicate the focus bias value.

7.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob in the clockwise direction and find the focus bias value at which the C1 error rate becomes about 200 (Refer to Note 2).

8.Press the [YES] button and display “ Manual backgroundManual backgroundManual backgroundManual background /Manual backgroundManual background b = Manual backgroundManual background ”.

9.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob in the counterclockwise di- rection and find the focus bias value at which the C1 error rate becomes about 200.

10.Press the [YES] button and display “ Manual backgroundManual backgroundManual backgroundManual background /Manual backgroundManual background c = Manual backgroundManual background ”.

11.Check that the C1 error rate is below 50 and ADER is 00. Then press the [YES] button.

12.If the “( Manual backgroundManual backgroundManual backgroundManual background )” in “ Manual backgroundManual backgroundManual backgroundManual background - Manual backgroundManual backgroundManual backgroundManual background - Manual backgroundManual backgroundManual backgroundManual background (Manual backgroundManual backgroundManual backgroundManual background)” is above 20, press the [YES] button.

If below 20, press the [MENU/NO] button and repeat the ad- justment from step 2.

13.Press the [ÊÊÊÊÊEJECT]¤ button and take out the disc.

Note 1: The relation between the C1 error and focus bias is as shown in the following figure. Find points A and B in the following figure using the above adjustment. The focal point position C is auto- matically calculated from points A and B.

Note 2: As the C1 error rate changes, perform the adjustment using the average vale.

C1 error

about 200

B

C

A

Focus bias value

 

 

 