4-4. MANUAL MODE
The Manual mode is designed to perform adjustments and operational checks on the set’s operation according to each individual function.
Usually, no adjustments are made in this mode.
However, the Manual mode is used to clear the memory before performing automatic adjustments in the Overall Adjustment mode.
4-4-2. How to set the Manual mode
1.Set the TEST MODE and press + key to set the Manual mode. Remote control LCD display
000AAASCC
2.Each test item is assigned with a
|
| Change Major |
|
| + key : Up |
| ||||||
|
| Item |
|
|
|
|
|
| key : Down |
| ||
|
| key |
|
| x key |
| ||||||
|
|
|
|
| ||||||||
> N |
| |||||||||||
|
|
|
|
|
|
|
|
| + key : Up |
| ||
|
|
|
|
|
|
|
|
|
| |||
|
| Change Middle |
|
|
| |||||||
|
| Item |
|
|
|
|
|
| key : Down |
| ||
|
| key |
|
| x key |
| ||||||
|
|
|
|
| ||||||||
> N |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| key : Up |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Change Minor |
|
| > N |
| ||||||
|
| Item |
|
|
|
|
|
|
| key : Down |
| |
|
|
|
|
|
|
|
| . |
| |||
|
|
|
|
|
|
|
|
|
|
|
| + key : Up |
|
|
|
|
|
|
| Change Adjustment | |||||
|
|
|
|
|
|
| Value | key : Down | ||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| Write Adjustment | X key : Write | |||
|
|
|
|
|
|
|
| Value | ||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
3.During each test mode, the display is changed from one to another each time DISPLAY key is pressed.
Address Value & Adjustment Value
LCD display
011 XXXSXX
Block Error Value & Adjustment Value
LCD display
011 XX BXX
ADIP Error Value & Adjustment Value
LCD display
011 XX AXX
Jitter Value & Adjustment Value
LCD display
011 XXXJXX
Asy Mmetry Feed Back Gain Value & Adjustment Value
LCD display
011 XX RXX
Power Adjustment Value
LCD display
731 XX VXX
Memory Monitor Mode
XXX: Each Value
XX: Adjustment Value
for Item number
Note: In the Power mode, the power adjustment value is only displayed.
4.During each test, press and hold down > N key or . key for a while to move the optical pickup on the sled outer or inner perimeter.
5.To terminate the Manual mode and return to the TEST MODE, press x key.
4-5. OVERALL ADJUSTMENT MODE
4-5-1. Outline of the function
This mode is designed to adjust the servo system automatically by going through all the adjustment items.
Usually, this mode is used to perform automatic adjustments when servicing the set.
For further information, refer to section 5. ELECTRICALADJUST- MENTS (page 12).