4-5. SOUND SKIP CHECK RESULT DISPLAY MODE

This set can display and check the error count occurring during record and play.

• Setting method of Sound Skip Check Result Display Mode

1.Setting the test mode. (See page 13)

2.Press the N or [REC] key on the set activates the sound skip check result display mode where the LCD displays as shown below.

When N or [REC] key on the set is pressed:

LCD display

000P * * R * *

E I B * * Total of record system error count

Total of play system error count

3.When N key or N > key on the remote commander is pressed, the total of error count is displayed on the LCD, and each time the > key is pressed, the error count descents one by one as shown below. Also, when . key is pressed, the error count ascends by one. If [REC] key on the set is pressed, the error count during record is displayed.

000

P * * R * *

 

 

 

 

 

000

E I B * *

000S t a t * *

000A d r s * *

000B E m p * *

000# # # # # #

**: Sound skip check items counter (hexadecimal)

###### : 6-digit address (hexadecimal) where a sound skipped last

4.When [REC] key on the set is pressed, the total of error count is displayed on the LCD, and each time the > key is pressed, the error count descents one by one as shown below. Also, when . key is pressed, the error count ascends by one. If N key is pressed, the error count during play is displayed.

000P * * R * *

000B O v r * *

000B f u l * *

000R t r y * *

000# # # # # #

**: Sound skip check items counter (hexadecimal)

###### : 6-digit address (hexadecimal) where a sound skipped last

Error code

 

Cause of error

Description of error

 

EIB

Sound error correction error

Playback

Stat

Decorder status error

Adrs

Cannot access the address

 

 

BEmp

Buffer becomes empty

 

BOvr

Buffer becomes full and sounds are

 

 

dumped

Recording Bful

Buffer capacity lowers and data are

 

 

forcibly written

 

Rtry

Retry count over

 

 

 

5.Quit the sound skip check result display mode, and press the x key to return to the test mode (display check mode).