Sony MT-MZR70-165, MZ-R90/R91 service manual

Models: MT-MZR70-165 MZ-R90/R91

1 51
Download 51 pages 22.19 Kb
Page 41
Image 41

Pin No.

Pin Name

I/O

 

 

Pin Description

 

 

 

 

 

 

 

 

System reset signal input from the MPC18A31FTA (IC901) “L”: reset

43

 

 

XRST

I

 

 

For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44

 

 

VSS

Ground terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

 

XTAL

O

Main system clock output terminal (16.9344 MHz)

 

 

 

 

 

 

 

 

 

 

46

 

EXTAL

I

Main system clock input terminal (16.9344 MHz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47

 

 

VDD

Power supply terminal (+2.4 V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

TSB SLV CTL

I/O

Two-way control signal bus with TSB slave circuit

Not used (open)

 

 

 

 

 

 

 

 

49

SPDL START SW

O

Spindle servo start switching signal output to the analog switch (IC504, 505)

 

 

 

 

 

 

 

 

50

OPEN CLOSE SW

I

Upper panel open/close detect switch (S801) input terminal (A/D input)

“L”: upper panel close, “H”: upper panel open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

51

XSHOCK

I

Recording shock detect signal input from the CXD2660GA (IC502)

 

 

 

 

 

 

 

 

 

52

 

 

FOK

I

Focus OK signal input from the CXD2660GA (IC502)

“H”: is input when focus is on (“L”: NG)

 

 

 

 

 

 

 

 

53

 

 

SQSY

I

Subcode Q sync (SCOR) input from the CXD2660GA (IC502)

 

 

“L” is input every 13.3 msec

Almost all, “H” is input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54

 

DQSY

I

Digital In U-bit CD format subcode Q sync (SCOR) input from the CXD2660GA (IC502)

 

“L” is input every 13.3 msec

Almost all, “H” is input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

 

XINT

I

Interrupt status input from the CXD2660GA (IC502)

 

 

 

 

 

 

 

 

 

 

 

 

56

 

T.MARK

I

T MARK switch (S803) input terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

57

REC WBL SW

O

Stable control signal is output when recording

 

 

 

 

 

 

 

 

 

 

58

 

SERON

O

Series power supply control signal output to the MPC18A31FTA (IC901)

 

 

 

 

 

 

 

 

59

 

XCHG

O

Charge control signal output to the MPC18A31FTA (IC901)

 

 

 

 

 

 

 

 

 

60

 

XTEST

I

Setting terminal for the test mode

“L”: test mode, normally: fixed at “H”

 

 

 

 

 

 

 

 

 

 

61

SET CODE0

I

Destination setting terminal for the test mode

 

 

 

 

 

 

 

 

 

 

 

62

SET CODE1

I

Destination setting terminal for the test mode

Not used (open)

 

 

 

 

 

 

 

 

 

 

63

SET CODE2

I

Destination setting terminal for the test mode

 

 

 

 

 

 

 

 

 

 

64

REG CTL PWM

O

Synchronizing external clock signal output to the MPC18A31FTA (IC901)

 

 

 

 

 

 

 

 

65

VRM PWM

O

VREM power supply voltage control PWM signal output to the MPC18A31FTA (IC901)

 

 

 

 

 

 

 

 

66

VC PWM

O

System power supply voltage control PWM signal output to the MPC18A31FTA (IC901)

 

 

 

 

 

 

 

 

67

SPDL PWM

O

Spindle servo drive voltage control PWM signal output to the MPC17A56FTA (IC901)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset signal output to the A/D, D/A converter (IC301), SN761056ADBT (IC501) and

68

 

XIC RST

O

 

CXD2660GA (IC502) “L”: reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

69

REC LED

O

REC LED drive signal output terminal

Not used (open)

 

 

 

 

 

 

 

 

70

 

 

SI1

I

Joint text data input from the remote commander with headphone

 

 

 

 

 

 

 

 

71

 

 

SO1

O

Joint text data output to the remote commander with headphone Not used (open)

 

 

 

 

 

 

 

 

72

 

 

SCK1

O

Joint data communication clock output to the remote commander with headphone

 

 

Not used (open)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

73

XHOLD SW

I

HOLD switch (S804) input terminal

“L”: hold on, “H”: hold off

 

 

 

 

 

 

 

 

 

 

 

 

 

74

 

 

VDD

Power supply terminal (+2.4 V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

 

TEX

I

Sub system clock input terminal

Not used (open)

 

 

 

 

 

 

 

 

 

 

 

76

 

 

TX

O

Sub system clock output terminal

Not used (open)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77

 

 

VSS

Ground terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

78

 

VBKAN

I

Sub power supply input terminal

 

 

 

 

 

 

 

 

 

 

 

 

79

 

S MON

I

Servo signal monitor input from the SN761056ADBT (IC501) (A/D input)

 

 

 

 

 

 

 

 

80

VB MON

I

Un-regulator power supply voltage monitor input terminal (A/D input)

 

 

 

 

 

 

 

 

81

CHG MON

I

Rechargeable battery voltage monitor input from the MPC18A31FTA (IC901) (A/D input)

 

 

 

 

 

 

 

 

82

VREF MON

I

Reference voltage monitor input from the SN761056ADBT (IC501) (A/D input)

 

 

 

 

 

 

 

 

83

 

WK DET

I

Set key starting detect signal input terminal (A/D input)

 

 

 

 

 

 

 

 

 

84

HALF LOCK SW

I

Open knob detect switch (S802) input terminal

“L”: normal position, “H”: open knob slid

 

 

 

 

 

 

 

 

85

RMC KEY

I

Remote commander with headphone key input terminal (A/D input)

 

 

 

 

 

 

 

 

 

86

SET KEY 1

I

Set key input terminal (A/D input)

(x, >, ., VOL +/– keys input)

 

 

 

 

 

 

 

 

 

 

 

 

 

– 49 –

Page 41
Image 41
Sony MT-MZR70-165, MZ-R90/R91 service manual