While recording

Symptom

Cause/Remedy

 

 

“NOT ENOUGH

• Recording is not possible when using a 1GB Hi-MD disc even when

POWER TO REC”

the battery level indication shows enough power remaining while the

appears and recording

recorder is stopped or playing. This is because of a mechanism that

cannot be done on a

disables recording when the remaining battery power is estimated by

1GB Hi-MD disc.

the recorder to be insufficient due to the high power consumption

 

required for 1GB Hi-MD disc recording.

 

, Connect the AC power adaptor to the recorder or insert a fully

 

charged rechargeable battery or a new alkaline dry battery.

 

 

The remaining recording

• This is a system limitation. 2.0MB is the capacity of the reserve

time appears as “–00:00”

domain.

and recording cannot be

 

done, even though

 

2.0MB of free space is

 

displayed.

 

 

 

The recorder always

• The group recording (“Group REC”) is set to “On”. (You cannot

creates a new group

overwrite tracks.)

when recording.

, Set the group recording setting to “Off” (page 37).

 

 

The first few seconds of

• If you start recording before the x indication appears in the display,

a track cannot be

data will not be recorded to the first few seconds of the first track.

recorded.

, Wait until the x indication appears before you start recording.

 

 

Recording cannot be

• You tried to record in MD mode on this recorder.

done correctly.

, Only Hi-MD mode can be used to record directly on this

 

recorder without using a computer. To record in MD mode,

 

connect the recorder to a computer and use the supplied software

 

(pages 22 and 30).

 

• Audio sources may not be securely connected.

 

, Disconnect the audio sources once and connect them again

 

(pages 21 and 34).

 

• There is no digital signal from the portable CD player.

 

, When recording digitally from a portable CD player, use the AC

 

power adaptor and disable the anti-skip function (such as ESP)

 

on the CD player.

 

• The analog recording was made using a connecting cord with an

 

attenuator.

 

, Use a connecting cord without an attenuator.

 

• Recording level is too small to record (when adjusting the recording

 

level manually).

 

, Pause the recorder and adjust the recording level (page 35).

 

• The recorder is connected to the computer.

 

, Disconnect the recorder from the computer when recording.

 

• The power sources was disconnected or a power outage occurred

 

during recording.

 

, The recording result is not recorded on the disc. Make recording

 

again.

 

 

72