3. MANUAL MODE

This is mode to adjust or check the operation of the set by function.

Operation of The Manual Mode

1.Enter the test mode (Display Check mode).

2.Press the [VOL+] key to activate the Manual mode where the LCD displays as shown below.

Display of the remote commander

000Manual

Number of 1000th place

(000 to 009)

3.During Manual mode, the optical pick-up moves outward or inward while the > or . key is pressed for several seconds respectively.

4.Each test item is assigned with a four-digit item number; 1000th place is a top item, 100th place is a major item, 10th place is a medium item, and unit place is a minor item.

Flow of manual mode operation:

MZ-RH910

5.The display changes a shown below each time the

[SEARCH/MENU] key is pressed.

Item Title Display

Remote commander LCD display

XXX* * * * * * # #

 

 

 

 

 

 

 

 

 

adjusted value

item number

 

 

 

 

 

 

item title

 

 

 

 

 

Address & Adjusted Value Display

Remote commander LCD display

XXX* * * S # #

 

 

 

adjusted value

item number

 

address

 

 

 

Jitter Value & Adjusted Value Display

Remote commander LCD display

XXX* * * J # #

 

 

 

 

 

adjusted value

item number

 

 

 

 

 

 

 

Top item switching

> key x key

Major item switching

> key x key

[VOL +] key: 1000th place of item number increase.

[VOL --]key: 1000th place of item number decrease.

[VOL +] key: 100th place of item number increase.

[VOL --]key: 100th place of item number decrease.

jitter value

Block/Bite Error Value & Adjusted Value Display

Remote commander LCD display

XXX* * * B # #

 

 

 

 

 

 

 

adjusted value

item number

 

 

 

 

 

 

 

 

 

 

 

 

 

block/bite error value

 

 

 

Medium item switching

> key x key

Minor item switching

[VOL +] key: 10th place of item number increase.

[VOL --]key: 10th place of item number decrease.

>key: 1st place of item number increase.

.key: 1st place of item number decrease.

Bite Error LPF Value & Adjusted Value Display *1)

Remote commander LCD display

XXX* * * L # #

 

 

 

 

 

 

 

adjusted value

item number

 

 

 

 

 

 

 

 

 

 

 

bite error LPF value

 

 

 

 

 

 

CEMAX Value & Adjusted Value Display *1)

Remote commander LCD display

XXX* * * C # #

Adjusted value variation

[VOL +] key: Increases the adjusted value.

[VOL --]key: Decreases the adjusted value.

Adjusted value write

Set [X]key:

Remote commander [--]key:

Adjusted value is written.

 

 

 

 

 

 

 

adjusted value

item number

 

 

 

 

 

 

 

 

 

 

 

CEMAX value

 

 

 

 

 

 

ADIP Error Value & Adjusted Value Display

Remote commander LCD display

XXX* * * A # #

 

 

 

 

 

 

 

adjusted value

item number

 

 

 

 

 

 

 

 

 

 

 

ADIP error value

 

 

 

 

 

 

Focus Drive Value & Adjusted Value Display

Remote commander LCD display

XXX* * * F # #

 

 

 

adjusted value

item number

 

focus drive voltage value

 

 

 

 

 

 

*1) It is skipped from the item number 5000 less than 8000.

6.To release the Manual mode, press the x key to return to the Display Check mode.

13