MZ-RH910

SECTION 5

ELECTRICAL ADJUSTMENTS

1.PRECAUTIONS FOR ADJUSTMENT

1.Adjustment must be done in the test mode only. After adjusting, release the test mode. A key having no particular description in the text, indicates a set key. Also, for the LCD display, the LCD on the remote commander is shown.

2.Use the following tools and measuring instruments.

Digital multi meter

Regulated dc power supply (two sets)

Ampere meter

Laser power meter

CD adjustment disc TDYS-1 (Part No. : 4-963-646-01)

MD1/HiMD1 hybrid adjustment disc MDW-74/GA2

Hi-MD3 adjustment disc HMD1GSDJ (Part No. : 8-892-388-38) *1

Remote commander in accessories (with LCD)

AC adapter in accessories

*1) Hi-MD3 adjustment disc (HMD1GSDJ) is consumable. Therefore if it is used 400 times, exchange it for a new.

2.ADJUSTMENT SEQUENCE

Adjustment must be done with the following order.

Adjustment order:

1. Entering the test mode

Note: Enter the test mode with a key.

2.Initialize the adjustment value

3.Power supply voltage adjustment

4.Charge function check

5.Laser power check

6.Setting the adjustment values

7.Servo Overall adjustment

8.Resume clear

9.Releasing the test mode

3.ADJUSTMENT OF THE EACH ITEM 3-1. Initialize The Adjustment Value

Procedure:

1.In the test mode (Display Check mode), press the [VOL--]key to enter the Overall adjustment mode.

2.Press the [REC/T MARK] key and display “911 ResOK?”.

3.Press the X key on the set or key on the remote commander to display “911 Reset!” and initialize the

adjustment values.

4.Press the x key and back to Display Check mode.

3-2. Power Supply Voltage Adjustment

Adjustment must be done with the following order.

3-2-1. Setting

Procedure:

1.Apply the voltage of 1.2 V to the battery terminals, and enter the test mode (Display Check mode).

2.Press the [VOL+] key to enter the Manual mode.

3.Press the [VOL+] key twice to display as follows.

Display of the remote commander

002POWER

4.Press the > key once, press the [VOL+] key once, and press the > key once again to display as follows.

Display of the remote commander

210PwrAdj

5.Repeat the next procedures (3-2-2. PwrAdj Adjustments), and adjust all contents of “table 3-2-1. PwrAdj Specifications”.

3-2-2. PwrAdj adjustments

Repeat the following procedures and adjust all contents of “table 3- 2-1. PwrAdj Specifications”.

Example Display (Item No. 2211)

211 VC1

**

 

 

 

 

 

 

 

 

 

adjustment value (hexadecimal)

Procedure:

1.Connect the digital multi meter to measuring point (refer to the following table) and CL433 (GND).

2.Press the > key to change the item numberr to 2211.

3.Adjust with [VOL+]/[VOL--]keys so that the value of digital multi meter becomes specification value.

4.Press the X key on the set or key on the remote commander to write the adjusted value. (Shifts to the next

item automatically)

5.Repeat adjustment from step 3 until item number 2233.

ItemNo.

Display

Specification value

Measuring point

 

 

 

 

 

2211

 

211 VC1 **

2.05V + 0.02V

CL8029

 

 

 

 

 

2212

 

212 VC1 Ni **

2.25V ± 0.01V

CL8029

 

 

 

 

 

2213

 

213 VC2 **

1.20V + 0.01V

CL8001

 

 

 

 

 

2214

 

214 DDC3 L **

3.10V ± 0.015V

CL658

 

 

 

 

 

2215

 

215 DDC3 H **

3.10V ± 0.015V

CL658

 

 

 

 

 

2216

 

216 REG1 L **

3.02V ± 0.02V

CL362

 

 

 

 

 

2217

 

217 REG1 H **

3.02V ± 0.02V

CL362

 

 

 

 

 

2218

 

218 REG2 1 **

2.275V ± 0.01V

CL518

 

 

 

 

 

2219

 

219 REG2 2 **

2.480V ± 0.01V

CL518

 

 

 

 

 

2221

 

221 REG2 3 **

2.740V ± 0.01V

CL518

 

 

 

 

 

2222

 

222 REG2 4 **

2.985V ± 0.01V

CL518

 

 

 

 

 

2223

 

223 REG3 **

2.52V ± 0.02V

CL511

 

 

 

 

 

2224

 

224 VREC 1 **

0.89V ± 0.02V

CL604

 

 

 

 

 

2225

 

225 VREC 2 **

1.08V ± 0.02V

CL604

 

 

 

 

 

2226

 

226 VREC 3 **

1.52V ± 0.02V

CL604

 

 

 

 

 

2227

 

227 VREC 4 **

2.27V ± 0.02V

CL515

 

 

 

 

 

2228

 

228 VREC 5 **

2.97V ± 0.02V

CL515

 

 

 

 

 

2229

 

229 VREC 6 **

0.94V ± 0.02V

CL604

 

 

 

 

 

2231

 

231 VREC 7 **

1.28V ± 0.02V

CL604

 

 

 

 

 

2232

 

232 VREC 8 **

2.57V ± 0.02V

CL604

 

 

 

 

 

2233

 

233 VREC 9 **

2.57V ± 0.02V

CL604

 

 

 

 

 

Note1:

**” is adjustment value (hexadecimal number).

Note2:

Ground point of all measuring points is CL433.

Note3:

Refer to page 17 for adjustment location.

 

Table 3-2-1. PwrAdj Specifications

16