![](/images/new-backgrounds/1019032/1903239x1.webp)
MZ-NH700/NHF800
Ver 1.1
3-8. Servo Overall Adjustment
Note1: Be sure to adjustment so that the set is horizontal and the LCD is upside. Unless performed in that state, it is not adjusted correctly.
Note2: If NG is displayed in the middle of this adjustments, perform
Procedure:
1.Insert the full charged
2.Press the
3.Insert the CD adjustment disc
4.Put the main unit horizontal so that the LCD becomes upside, and press the . key.
5.Wait until “CD OK” is displayed on the LCD.
6.Insert the MD1/HiMD1 hybrid adjustment disc
7.Put the main unit horizontal so that the LCD becomes upside, and press the > key.
8.Wait until “MD1 OK” is displayed on the LCD.
9.Insert the
10.Put the main unit horizontal so that the LCD becomes upside, and press the [VOL+] key.
11.Wait until “HMD OK” is displayed on the LCD.
12.Eject the disc.
13.Put the main unit horizontal so that the LCD becomes upside, and press the
14.Wait until “OfstOK” is displayed on the LCD.
15.Press the x key and back to the Display Check mode.
3-9. Resume Clear
Procedure:
1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.
2.Press the [VOL+] key once, press the > key once, press the
3.Press the X key to resume clear.
4.Press the x key four times and back to the Display Check mode. And remove the
3-10. Releasing The Test Mode
Refer to the “SECTION 4. TEST MODE”.
Note: Once the test mode is activated with this application, the test mode is then activated forcibly by only turning on the power.
After the repair completed, be sure to release the test mode by using this application once more.
20