3-6. Laser Power Check
Procedure:
1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.
2.Open the lid and press the . key continuously until the optical
3.Set the laser power meter so that the laser beam from the optical
4.Press the
Display
9 DESIGN
5.Press the > key three times to select the item number 9111 and display as follows.
Display
111
###S**
6.Confirm that the value of laser power meter is 0.67 mW ± 21%.
7.Press the > key to select the item number 9112.
8.Confirm that the value of laser power meter is 0.76 mW ± 18%.
9.Press the > key to select the item number 9113.
10.Confirm that the value of laser power meter is 6.25 mW ± 12%.
11.Press the x key four times and back to the Display Check mode.
3-7. Setting The Adjustment Values
3-7-1. Hi-MD3 setting
Preparation:
1.Perform calculation every item based on the data given by the
2.Convert the calculated value into hexadecimal number.
Note: The
Item No. | Calculating formula (*3) |
|
|
0211 | Pr_nominal / 0.05 |
|
|
(*1) | Por / 0.05 |
|
|
0212 | Kr ⋅ (−100) |
|
|
0213 | Pw_nominal / 0.05 |
|
|
(*2) | Ppw / 0.05 |
|
|
0214 | Kw ⋅ (−100) |
|
|
0215 | Prmin / 0.05 |
|
|
0216 | Pwmin / 0.05 |
*1) If the “Pr_nominal” value is indicated, use the “Pr_nominal” value and not used “Por” value.
*2) If the “Pw_nominal” value is indicated, use the “Pw_nominal” value and not used “Ppw” value.
*3) Round off after the decimal point.
Table
MZ-NH700/NHF800
Ver 1.1
Example of Calculation:
Item No. | Parameter |
| Result | ||
|
| ||||
Decimal | Hexadecimal | ||||
|
|
| |||
|
|
|
|
| |
0211 | Pr_nominal | 2.50 mW | 50 | 32h | |
|
|
|
|
| |
0212 | Kr | −0.3 %/°C | 30 | 1Eh | |
|
|
|
|
| |
0213 | Pw_nominal | 7.35 mW | 147 | 93h | |
|
|
|
|
| |
0214 | Kw | −0.4 %/°C | 40 | 28h | |
|
|
|
|
| |
0215 | Prmin | 1.9 mW | 38 | 26h | |
|
|
|
|
| |
0216 | Pwmin | 5.8 mW | 116 | 74h |
Procedure:
1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.
2.Press the > key once, press the [VOL+] key once, and press the > key once again to display as follows.
Display
210 DiscPr
3.Press the > key once to select the item number 0211.
4.Adjust with
5.Press the X key to write the adjusted value.
6.Press the > key to next item.
7.Repeat adjustment from step 4 until item number 0216.
3-7-2. Other setting
1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.
2.Press the > key five time to select the item number 0113 and display as follows.
Display
113
###S**
adjustment value (hexadecimal)
3.Press the
4.Press the X key to write the adjusted value.
Destination | Model Type | ||
|
| ||
| |||
| |||
|
|
| |
US | − | 50 | |
|
|
| |
Canadian, Australian | 20 | 30 | |
|
|
| |
AEP, UK, East European | A0 | B0 | |
|
|
| |
E18, Hong Kong, Korean, | 25 | 34 | |
Chinese, Tourist | |||
|
| ||
|
|
| |
E91, Mexican | 20 | − | |
|
|
|
• Abbreviation
E18: 100V - 240V AC area in E model
E91: 220V AC area in E model
Table
19