object into it fire.
to avoid electrical shock or
Note
• Do not tighten the screws too much. Doing so could damage some of the internal components of the projector.
6 Turn the projector back over.
7 Connect the power cord and turn the projector to standby mode.
8 Press the following keys on the control panel in the following sequence for less than five seconds each: RESET, <, ,, ENTER.
Caution
• Do not put your hands into the lamp replacement spot, or not fall any liquid or
Close the lamp cover and tighten the screws.
5
Insert the new lamp all the way in until it is securely in place. Tighten the screws. Fold up the handle.
Notes
• Be careful not to touch the glass surface of the lamp.
• The power will not turn on if the lamp is not secured properly.
4

Notes

Be sure to use the LMP-P260 Projector Lamp for replacement. If you use lamps other than LMP-P260, the projector may cause a malfunction.

Be sure to turn off the projector and unplug the power cord before replacing the lamp.

We recommend that you also clean the air filter whenever you replace the lamp.

Disposal of the used lamp

As the used lamp contains Mercury, dispose of the lamp according to local, state or federal laws.

As the materials used in this lamp are similar to those of a fluorescent lamp, you should dispose of a used projector lamp in the same way as a fluorescent lamp.

Cleaning the Air Filter

The air filter should be cleaned every 1500 hours.

Remove dust from the outside of the ventilation holes with a vacuum cleaner.

When it becomes difficult to remove the dust from the filter with a vacuum cleaner, remove the air filter and wash it.

1 Turn off the power and unplug the power cord.

Maintenance

Maintenance 39 GB