Connecting the SCSI

Bus Cable

(SAITe1300-S only)

Connect the SAITe1300-S (SCSI model) and the host computer with a SCSI cable. This section describes how to do so. Use an Ultra 160/m SCSI LVD cable commonly sold in stores to connect the unit to the SCSI bus. The SAITe1300-S uses a 68-pin half pitch connector.

Caution

Do not connect the SAITe1300-S to a HVD (High Voltage Differential) SCSI bus. If you do, the unit or other devices on the SCSI bus may be damaged.

Turn off all the connected devices before connecting the SCSI cable, including the SAITe1300-S and the host computer.

If the SAITe1300-S is the last or only device on the SCSI bus, make sure that you connect the supplied terminator to the open connector.

Make sure that the SCSI connectors are securely connected.

With LVD (Low Voltage Differential) SCSI, make the total length of the SCSI cable (internal and external) connecting the host computer and the device at the end of the SCSI bus shorter than 12 m (39.4 ft.). On an LVD bus with a single device, make this length shorter than 25 m (82 ft.). The SAITe1300-S internal cable length is 25 cm (9.8 in.).

SCSI cables cannot be branched.

1 Make sure that the host computer and the SAITe1300-S are off.

2 Connect the SCSI cable and terminator as shown below.

The SCSI cable can be up to 24.7 m (81 ft.) long. (The SAITe1300-S internal cable length is 25 cm (9.8 in.).)

SCSI connector

Host computer

Terminator

SCSI cable

A SCSI bus allows you to connect up to fifteen peripherals to the host computer, including the unit.

When the SAITe1300-S is one of several devices on the SCSI bus

1 Turn off all SCSI devices on the SCSI bus, including the SAITe1300-S.

Caution

When connecting or disconnecting a SCSI cable to SCSI devices (including the SAITe1300-S), turn off all the SCSI devices. Failing to do so may result in damage.

2 Connect the SCSI cable to the next device on the SCSI bus, connect the terminator to the last device on the bus, then issue the host command to resume operation.

SCSI

connector

SCSI devices

Host computer Terminator

SCSI cable

Notes

The total length of the SCSI cables between the host computer and the last device should be less than 12 m (39.4 ft.). (The SAITe1300-S internal cable length is 25 cm (9.8 in.).)

If the SAITe1300-S is the last device on the SCSI bus, make sure that you connect the supplied terminator to the open connector.

Connecting the SCSI Bus Cable (SAITe1300-S only)

19