When the alarm data reaches more than 100

The oldest one will be erased.

To reset the alarm data

Press MENU RESET while the ALARM DATA menu is on the screen.

The alarm count shows “000”.

Recording the Alarm Data on theTape

1

2-4

5

1 Turn on the power of the equipment to be used.

2 Press MENU and MENU V until “3” of the MAIN MENU flashes on the monitor screen.

3 Press MENU B.

The ALARM SET menu appears.

ALARM SET

ALARM MODE

A1

 

 

ALARM SPEED

6H

 

ALARM DURATION

20sec

 

ALARM DATA REC

OFF

 

TAPE END WARN.

COUNTER

 

CLOG DETECTION

ON

 

SERIES REC

OFF

 

<NEXT PUSH >

 

SELECT :

DATA SET : +/RETURN : MENU

4 Press MENU V to move the flashing to the setting of ALARM DATA REC and set to ON by pressing MENU + or –.

ALARM SET

ALARM MODE

A1

 

 

ALARM SPEED

6H

 

ALARM DURATION

20sec

 

ALARM DATA REC

ON

 

TAPE END WARN.

COUNTER

 

CLOG DETECTION

ON

 

SERIES REC

OFF

 

<NEXT PUSH >

 

SELECT :

DATA SET : +/RETURN : MENU

ON (in recording mode): when the recording comes to the end, the VCR rewinds the tape to the beginning and starts recording the alarm data on the ALARM DATA menu up to 100 data.

ON (in playback mode):

1When the tape is inserted, the VCR rewinds the tape to the beginning.

2Press SEARCH until “AL L” flashes in the display window.

3Press REW m.

The ALARM DATA list appears.

To change the page of the ALARM DATA, press FF M or REW m. (You may have to press the button a few times.)

In the display window

ALARM DATA

 

 

1 0 0. 1 2 – 0 3 1 9 : 0 0

9 0. 0 0 – 0 0 0 0 : 0 0

9 9. 1 1 – 0 1 2 3 : 0 0

8 9. 0 0 – 0 0 0 0 : 0 0

9 8. 1 0 – 2 5 1 5 : 0 0

8 8. 0 0 – 0 0 0 0 : 0 0

9 7. 1 0 – 2 5 0 8 : 0 0

8 7. 0 0 – 0 0 0 0 : 0 0

9 6. 1 0 – 2 5 0 6 : 0 0

8 6. 0 0 – 0 0 0 0 : 0 0

9 5. 0 0 – 0 0 0 0 : 0 0

8 5. 0 0 – 0 0 0 0 : 0 0

9 4. 0 0 – 0 0

0 0 : 0 0

8 4. 0 0 – 0 0

0 0 : 0 0

9 3. 0 0 – 0 0

0 0 : 0 0

8 3. 0 0 – 0 0

0 0 : 0 0

9 2. 0 0 – 0 0

0 0 : 0 0

8 2. 0 0 – 0 0

0 0 : 0 0

9 1. 0 0 – 0 0

0 0 : 0 0

8 1. 0 0 – 0 0

0 0 : 0 0

NEXT DATA:

RETURN : MENU

On the monitor

4Press MENU + or – to set the alarm count and then press FF M.

The tape runs to the set alarm count and the playback picture appears in the still mode.

Example:

To go to the 11th alarm count

Press MENU + or – to display 11 and press

FFM. The alarm count in the display window counts down and becomes 00 after 10.

To go to the 15th alarm count after going to the 11th

Press MENU + or – to display 04 and press FF M until 00 appears.

To go back to the 7th alarm count after going to the 11th

Press MENU + or – to display 04 and press REW m until 00 appears.

37