R,B-gain (Effective only when WB mode = Manu)

R-gain Min.

[A000]

 

 

:

:

 

 

Standard

[A080]

 

 

:

:

 

 

R-gain Max.

[A0FF]

 

 

 

 

B-gain Min.

[A100]

 

 

:

:

 

 

Standard

[A180]

 

 

:

:

 

 

B-gain Max.

[A1FF]

 

 

Video Process Setting

Pedestal

Pedestal Min.

[AD71]

 

 

:

:

 

 

Standard

[AD80]

 

 

:

:

 

 

Pedestal Max.

[AD8F]

 

 

Note

The settings that can actually be made are limited to 16 levels, including [AD80h].

Gamma ON/OFF

ON

[E880]

 

 

OFF

[E800]

 

 

Sharpness

Sharpness Min.

[A500]

 

 

:

:

 

 

Standard

[A580]

 

 

:

:

 

 

Sharpness Max.

[A5FF]

 

 

Nega/Posi

posi

[EAB1]

 

 

nega

[EAB0]

 

 

The operation of AGC, CCD Iris, AWB, and ATW is not guaranteed when nega is set.

RS-232C Command List

System Settings

Memory Load Factory/Bank A/Bank B

Load Factory

[EF12]

 

 

Load from A

[EF00]

 

 

Load from B

[EF01]

 

 

Memory Save Bank A/Bank B

Save to A

[EBFA]

 

 

Save to B

[EBFB]

 

 

Output Sel. VBS/YC

VBS

[EA81]

 

 

YC

[EA80]

 

 

H-Phase

Shift –Max

[A400]

 

 

:

:

 

 

Standard

[A480]

 

 

:

:

 

 

Shift +Max

[A4FF]

 

 

Only effective when the camera is operated with external synchronization. Other than that, the camera returns a [CERR].

16

Page 16
Image 16
Sony XC-555P technical manual Video Process Setting, System Settings