Note : Follow the disassembly procedure in the numerical order given.
3-1. LOADING PANEL
•In order to remove the front panel block when the power supply does not turn on, rotate the cam with tapering driver as the figure shows, and the loading part will be moved.
Then pull out the loading part by your hand to remove the loading panel as the figure shows. After that take out the front panel block.
Loading panel
Tapering driver
Loading part
3-2. BASE UNIT (BU-5BD27)
1Turn the cam to the direction of arrow (counter clock wise) by tapering driver.
3Screw (DIA. 12), floating
4 Remove the Base unit
2Take off the tray.