Control Elements
Applying a preset: Depress APPLY for1 sec., LED flashes;
use UP/DOWN to select preset no.;
depress APPLY again, LED goes out
Operation safety:
Presets can not be changed by accident
Info
If you want to apply various presets depress APPLY for one second. The APPLY LED starts to flash indicating that the APPLY mode is activated. You can step through the preset list with UP and DOWN. Once you have a preset that you want to apply depress APPLY again. The APPLY LED goes out indicating that the preset is applied.
In case you want to quit the APPLY mode without applying the new preset simply press STORE.
To increase operation safety it is impossible to apply presets by simply depressing UP or DOWN. The UP and DOWN status- LEDs will not flash indicating that the input is not accepted. You have to depress STORE or APPLY for one second in order to activate the UP and DOWN buttons.
Depressing STORE and APPLY simultanouesly for about one 12 second gets you into a hardware dialogue, called INFO. The LC- display shows status informations of the digital data stream.
With UP/DOWN you will jump from one page to the next or previous. If a selection is provided use APPLY to select.
1.Software version and date
2.Selecting inputs:
The SPECTRALIZER automatically searches for an input signal. If both inputs are connected the AES/EBU input will be selected first. If you want to select the
AES/EBU input detected
or:
no AES/EBU input detected
Press APPLY (if AES/EBU is detected):
AES/EBU input with wordclock detected
12 | Spectralizer |