Set all controls to the starting positions:
INPUT GAIN 0; FREQUENCY 1k; DENSITY 0; 2ND HARMONIC 0%; 3RD HARMONIC 0%; MIX 0%.
1.Depress ACTIVE. The status-LED illuminates.
2.Set MIX to 50%. You will notice an increase in high frequencies above 1kHz (starting position FREQUENCY).
3.Set DENSITY to 1, to increase the audibility of the harmonics in the next step.
4.Set 2ND HARMONIC to 50% and 3RD HARMONIC to 30%.
5.If you are using full scale material for this initial test drive the CLIP LEDs may illuminate. Reduce the INPUT GAIN to give additional headroom for the new harmonics.
6.To compare original and processed signal press ACTIVE. The status LED goes out.
Use the SOLO button to monitor the added harmonics precisely.
Quick-Start
Input
Encoder
Original
Effect
Frequency-
Encoder |
Highpass- |
Filter |
Generator |
2nd Harmonic |
Encoder |
Kick- Density-
Encoder | Encoder |
Generator | |
3rd Harmonic | |
Encoder |
Solo-
Taste
Mix-
Encoder
Flow Chart
Diagram 1: Signalflow Spectralizer
Spectralizer | 7 |