![](/images/new-backgrounds/1090927/9092749x1.webp)
MODEL | TROUBLESHOOTING | |
Figure 8 |
|
|
Contactor Coil and MOV Check |
|
|
Actuator |
|
|
C | F |
|
B | E |
|
A | D |
|
|
| MOV |
TOP VIEW |
| LEFT SIDE VIEW |
1.Disconnect power at circuit breaker.
2.Remove control panel and disconnect
3.Depress actuator on top of contactor. Actuator should travel freely and spring back when released.
4.Check for continuity between contacts A and D as shown in top view. There should be no continuity.
5.Repeat Step 4 for contacts B and E and for contacts C and F.
6.Place test leads on contactor coil terminal as shown in left side view.
7.Check resistance.
8.If resistance is not approximately 390 (+/- 40) ohms, remove MOV and recheck coil resistance. If resistance is now approximately 390
9.Reconnect all wires.
TROUBLESHOOTING