MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS

INSTALLATION

Step 2: Electric Connection

A field connection Fuse Block is located at the rear of the unit, lower left side. A hole is provided for a 3/4” conduit fitting (solid or flex). Rear cover and fuse block cover must be removed to gain access to fuse block. Refer to Figure 2.

Be sure that the input voltage matches the requirement on the serial plate. The unit is factory wired per customer order.

!WARNING

A POSITIVE GROUND CONNECTION IS ESSENTIAL. DO NOT ALLOW ANY TAMPERING OR ADJUSTMENT OF ANY CONTROL OR WIRING. THE UNIT IS FACTORY SET. ADJUSTING ANY INTERNAL COMPONENT OTHER THAN THE MAIN FUSE BLOCK CAN VOID THE WARRANTY.

THIS UNIT REQUIRES A KIT TO BE FIELD CONVERTED FROM THREE-PHASE TO SINGLE- PHASE OR VICE-VERSA. CONSULT FACTORY FOR PHASE CHANGES.

All 208-220-240 and 480 volt units will have three fuse block sections, “L1-L2-L3”, for use with either 3-wire 3-phase or 2-wire, single-phase, 50 or 60 Hz. All 380V and 415V units will have four fuse block sections, “L1- L2-L3-N,” for use with European style 4-wire 3-phase with neutral.

Figure 2

 

 

Serial

 

 

Plate

 

 

Fuse Block

 

 

3/4" Conduit

Fuse Block Cover

 

Fitting Hole

 

 

(shown removed)

 

 

 

Rear Cover

OPERATORS MANUAL 1178387 REV 2

PAGE 7