Southbend EZ-3, EZ-5 manual Idle Element Resistance Check

Models: EZ-5 EZ-3

1 42
Download 42 pages 46.22 Kb
Page 26
Image 26

TROUBLESHOOTING

TROUBLESHOOTING

MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS

Figure 9

Idle Element Resistance Check

Model EZ-3

Model EZ-5

High Limit

Idle Element Plug

1.Disconnect power at circuit breaker.

2.Remove control panel.

3.Disconnect idle element plug (PL3).

4.Place test leads as shown above.

5.Check to see if resistance is within +/- 10% of values in the following table:

 

Model EZ-3

Model EZ-5

Voltage

Resistance (Ohms)

Resistance (Ohms)

 

 

 

208

115

87

220

129

97

240

154

115

380

385

289

415

459

344

480

614

461

6. Remove one test lead, place on ground, check for short circuit.