FIGURE 5: EASY CALIBRATION SCREEN
preprogrammed tire sizes tap both
the "MODE" and "FUNCTION" buttons simultaneously. When you reach the desired tire size press the "FUNCTION" button once to select it and exit Easy Calibration Mode.
Roll Out Method
The roll out method will provide the most accurate computer calibration
and can take into account variables such as inflation pressure, rim width and rider weight.
1.Extend a tape measure out to 3000mm (120 inches) and lock it in place.
2.With your tire inflated to its proper pressure, place the valve at the 6:00 position (at the bottom) directly over the start of the measuring tape.
3.Roll the wheel one complete revolution until the valve stem is again at the 6:00 position. Read the tape directly under the valve and note the distance in millimeters. (To convert inches to millimeters, multi- ply inches by 25.4). Use this num- ber to replace the default (default value is 2148) when programming your computer. (See figure 6)
7