Step 8: Check Installation
Refer to Installer Checklist on the back cover and make sure that unit is installed correctly.
Moving Unit to a New Location
To prevent damage while moving the unit, the shipping materials MUST BE reinstalled.
Reinstallation of Shipping Materials
Disconnect washer from electrical supply.
Remove front access panel by removing two screws.
Place the shock sleeves on all four shock absorbers. Refer to Figure 14.
Insert hooked end of shipping brace into the open slot of the motor mount. Attach with bolts and lockwashers. Refer to Figure 14.
Reinstall front access panel.
1
2 4
3
H336I
1Shock Sleeves
2Motor Mount
3Bolts and Lockwashers
4Hooked End of Shipping Brace
Figure 14
Refer to step 5 for proper procedures whenever the unit is moved.
Installation
Electrical Requirements
NOTE: The wiring diagram is located behind the control panel, inside the control hood.
WARNING
To reduce the risk of fire, electric shock, serious injury or death, all wiring and earthing MUST abide with local electrical codes. It is the customer’s responsibility to have the wiring and fuses checked by a qualified electrician to make sure the laundry room has adequate electrical power to operate the washer.
W246
DO NOT OVERLOAD
CIRCUITS
DO NOT USE AN
ADAPTER
DO NOT USE AN
EXTENSION CORD
D009I
Figure 15
NOTE: Refer to the washer nameplate for proper voltage and Hertz the washer is designed to operate on. Refer to Figure 16.
1
H129P
1Nameplate
Figure 16
801561 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 13 |