Installation

240 Volt, 50 Hertz

The washer is designed to be operated on a separate branch, polarized, three-wire, effectively earthed,

240 Volt, 50 Hertz, AC (alternating current) circuit protected by a 10 Ampere fuse, equivalent fusetron or circuit breaker.

WARNING

To reduce the risk of an electric shock or fire, DO NOT use an extension cord or an adapter to connect the washer to the electric power source.

W082

Earthing Instructions

The washer must be earthed. In the event of malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. The washer is equipped with a cord having an equipment-earthing conductor. The washer must be plugged or hardwired into an appropriate power source that is properly installed and earthed in accordance with all local codes and ordinances.

WARNING

Improper connection of the equipment- earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the washer is properly earthed.

W032

NOTE: Have a qualified electrician check the polarity of the power source.

DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT. DO NOT OVERLOAD CIRCUITS!

Do not operate both a washer and gas dryer on the same circuit. Use separately fused 10 Amp circuits.

120 Volt, 60 Hertz with 3-Prong Grounding Plug

The washer is designed to be operated on a separate branch, polarized, three-wire, effectively earthed, 120 Volt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse, equivalent fusetron or circuit breaker.

The three-prong earthed plug on the power cord should be plugged directly into a polarized three-slot effectively earthed receptacle rated 110/120 Volts AC (alternating current) 15 Amps. Refer to Figure 17 to determine correct polarity of the wall receptacle.

Earthing Instructions

The washer must be earthed. In the event of malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. The washer is equipped with a cord having an equipment-earthing conductor and a 3-prong earthing plug. The plug must be plugged into an appropriate outlet that is properly installed and earthed in accordance with all local codes and ordinances.

WARNING

Improper connection of the equipment- earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the washer is properly earthed.

W032

DO NOT modify the plug provided with the washer – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

NOTE: Have a qualified electrician check the polarity of the wall receptacle. If a voltage reading is measured other than that illustrated, the qualified electrician should correct the problem.

WARNING

This unit is equipped with a three-prong (earthing) plug for your protection against shock hazard and should be plugged directly into a properly earthed three-prong receptacle. Do not cut or remove the earthing prong from this plug.

W477

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

801561