Installation/Operation Supplement
Gases and Configurations
|
|
| Supply |
| Burner |
|
|
| Burner |
Country |
|
|
| Orifice | Capacity/ | Diameter, |
| ||
Gas Type | Group | Pressure, |
| Quantity | Orifice | ||||
Code |
| Pressure, | Model | mm | |||||
|
| mbar |
|
| Part No. | ||||
|
|
|
| mbar |
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
DK/NO/ | Natural Gas | E | 20 |
| 8.9 | 120 | 4.8 | 3 | M411372 |
|
|
|
| 8.0 | 170 | 4.8 | 4 | M411372 | |
SE/FI/CZ/ |
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |
EE/LV/LT/ | L.P. Gas | B/P | 30 |
| No Governor | 120 | 2.6 | 3 | M411376 |
SI/SK |
| ||||||||
|
|
|
|
| 170 | 3.4 | 3 | M400997 | |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| Natural Gas | E | 20 |
| 8.9 | 120 | 4.8 | 3 | M411372 |
|
|
|
|
| 8.0 | 170 | 4.8 | 4 | M411372 |
|
|
|
|
|
|
|
|
| |
DE** | L.P. Gas | B/P | 30 and No Governor or 26.4 | 120 | 2.6 | 3 | M411376 | ||
|
|
|
| or | 170 | 3.4 | 3 | M400997 | |
|
|
|
|
| |||||
|
|
| 50** and No Governor or |
|
|
|
| ||
|
|
|
| 28.7 |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
| Natural Gas | LL | 25 |
| 12.0 | 120 | 4.8 | 3 | M411372 |
NL |
|
|
|
|
| 170 | 4.8 | 4 | M411372 |
|
|
|
|
|
|
|
|
| |
L.P. Gas | B/P | 30 |
| No Governor | 120 | 2.6 | 3 | M411376 | |
|
| ||||||||
|
|
|
|
|
| 170 | 3.4 | 3 | M400997 |
|
|
|
|
|
|
|
|
| |
| Natural Gas | E+ | 20 or 25 | No Governor* | 120 | 4.2 | 3 | M402995 | |
BE/FR* |
|
|
|
|
| 170 | 3.8 | 4 | M402997 |
|
|
|
|
|
|
|
|
| |
L.P. Gas | 3+ | 28 or 37 |
| No Governor | 120 | 2.6 | 3 | M411376 | |
|
| ||||||||
|
|
|
|
|
| 170 | 3.4 | 3 | M400997 |
|
|
|
|
|
|
|
|
|
|
GB/IE/PT/ | Natural Gas | E | 20 |
| 8.9 | 120 | 4.8 | 3 | M411372 |
|
|
|
| 8.0 | 170 | 4.8 | 4 | M411372 | |
ES/IT/GR/ |
|
|
|
|
|
|
|
|
|
L.P. Gas | 3+ | 28 or 37 |
| No Governor | 120 | 2.6 | 3 | M411376 | |
LU/CH |
| ||||||||
|
|
|
|
|
| 170 | 3.4 | 3 | M400997 |
|
|
|
|
|
|
|
|
|
|
| Natural Gas | E | 20 |
| 8.9 | 120 | 4.8 | 3 | M411372 |
AT** |
|
|
|
| 8.0 | 170 | 4.8 | 4 | M411372 |
|
|
|
|
|
|
|
|
| |
L.P. Gas | B/P | 50** |
| 26.4 | 120 | 2.6 | 3 | M411376 | |
|
| ||||||||
|
|
|
|
| 28.7 | 170 | 3.4 | 3 | M400997 |
|
|
|
|
|
|
|
|
|
|
CY/IS/MT | L.P. Gas | B/P | 30 |
| No Governor | 120 | 2.6 | 3 | M411376 |
|
|
|
|
| 170 | 3.4 | 3 | M400997 | |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| Natural Gas | H | 25 |
| 8.9 | 120 | 4.8 | 3 | M411372 |
HU |
|
|
|
| 8.0 | 170 | 4.8 | 4 | M411372 |
|
|
|
|
|
|
|
|
| |
L.P. Gas | B/P | 30 |
| No Governor | 120 | 2.6 | 3 | M411376 | |
|
| ||||||||
|
|
|
|
|
| 170 | 3.4 | 3 | M400997 |
|
|
|
|
|
|
|
|
|
|
| Natural Gas | H | 20 |
| 8.9 | 120 | 4.8 | 3 | M411372 |
PL |
|
|
|
| 8.0 | 170 | 4.8 | 4 | M411372 |
|
|
|
|
|
|
|
|
| |
L.P. Gas | 3P | 37 |
| No Governor | 120 | 2.6 | 3 | M411376 | |
|
| ||||||||
|
|
|
|
|
| 170 | 3.4 | 3 | M400997 |
|
|
|
|
|
|
|
|
|
|
Table 1
Burner orifice information at
*For Natural Gas, Group E+ applications, convert using L.P. Gas model and replace burner orifices.
**For L.P. Gas, Group B/P with 50 mbar supply pressure, convert using Natural Gas model and appropriate burner orifices.
16 | © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT | M414881 (EN) |