NOTE: Refer to Table 2 for sizing of steam lines. Piping must also be sized accordingly for length of runs, and number of elbows.
1 | Supply | 8 | 457 mm (18 in.) Drop |
2 | 305 mm (12 in.) Riser | 9 | Solenoid Valve (Supplied with machine) |
3 | 10 | Steam Bonnet | |
4 | Condensate Return Line from Supply Line | 11 | Flexible Line |
5 | Return | 12 | Union |
6 | Check Valve | 13 | Trap with |
7Vacuum Breaker (Optional)
Figure 3
Steam Pressure bar (PSI) | Minimum Pipe Diameter | Steam Trap Size* | |
(Pounds Condensate/Hour) | |||
|
| ||
|
|
| |
5.3 - 6.9 | 3/4 in. NPT | 160 | |
|
|
|
* Based on 100 PSI.
Table 2