Installing the washer-dryer 9
Connecting the drain hose
It is possible for the water to be discharged into a
sink, standpipe or drainpipe, but an air break must be
available at a minimum 20 height to prevent the
machine from siphoning (Fig. 6).
Standpipe Drain System - Installations require a
minimum 1 ¼ (3.2 cm) diameter standpipe with a
minimum carry away capacity of 7 gallons (26 liters)
per minute.
Wall or Floor Standpipe Drain System - The top of the
standpipe must be between 25 (62 cm) - 34 (86
cm) from the bottom of the washer (Fig. 4).
Sink Drainpipe System - Entry into the sink drain
system must be above the trap (Fig. 5). When routing
the drain hose through cabinets or walls, use a
protective material such as electrical or duct tape to
cover sharp edges that could damage the drain hose.
Use a suitable clamp to secure the drain hose to the
“Y branch or the disposer (Fig. 7). With a sink
drainpipe system, you may connect directly: 1) to a
disposer by following the manufacturers attachment
25" (62 cm) min.
with an air break
Laundry Sink Drain
Sink Drain W/ "Y" Branch Tailpiece
Fig 5
method. 2) directly to a “Y branch tail piece
(available at most hardware stores). 3) Through the
floor to a separate trap. The trap must be vented to
prevent siphoning. To provide proper venting, install
an Air Gap Kit (available at most hardware stores). 4)
To the faucet using a Faucet Adapter Kit (available
separately).
IMPORTANT:Makesure that the drain
hose is not kinked and that water flow is
not restricted.
Use a U-Clamp (provided in your accessories
packet) or suitable item to secure the outlet end
of the drain hose (pre-installed on the back of
your machine).
Insert the outlet end of the drain hose into the
standpipe, wall or floor drain (Fig. 6). NOTE:
The outlet end of the drain hose MUST be at
least 20 (50 cm) above the base of the
machine. No more than 6 of the drain hose
should be inserted into the drain pipe to prevent
siphoning.
Use a strap, cable tie, or similar item to hold the
hose or the U-Clamp in place.
Floor Standpipe
20" (50 cm) min.
with an air break
25" (62 cm) min.
34" (86 cm) max.
6" max.
Standpipe
U-Clamp
Fig 6
A & B = 25" (62 cm) min. / 34" (86 cm) max.
Floor Standpipe Wall Standpipe
A
B
Fig 4
20" (51.8 cm) min.
34" (86 cm) max.
Standpipe
"Y" Tail Piece
This connection MUST be
before drain trap and at
least 20" (50.8 cm) above
the floor where washer will
be installed.
Cable tie
Floor Standpipe w/ "Y" Branch Tail Piece
Fig 7