Manuals
/
SPX Cooling Technologies
/
Household Appliance
/
Humidifier
SPX Cooling Technologies
none user manual
Models:
none
1
30
32
32
Download
32 pages
104 b
25
26
27
28
29
30
31
32
<
>
Troubleshooting
Install
Maintenance
Motor Wiring
Fluid Cooler Cleaning
Air wet-bulbtemperature Cold process fluid temperature will also vary with the wet-bulbtemperature of the air entering the fluid cooler. Reduced wet-bulbtemperatures will result in colder process fluid tem- peratures. However, the cold process fluid temperature will not vary to the same extent as the wet-bulb.For example, a 11C reduction in wet-bulbmay result in only a 8C reduction in cold process fluid temperature
How to
Safety
SPX Cooling Technologies Services
Page 30
Image 30
Page 29
Page 31
Page 30
Image 30
Page 29
Page 31
Contents
Marley MC Fluid Cooler
Page
Contents
Safety First
Preparation
Fluid Cooler Location
Preparation
Receiving Fluid Cooler
Installation
Shipment
Hoisting Fluid Cooler
Fluid Cooler Installation
Installation
Motor Wiring
When using a starter
Installation
Installation
When using a two-speed starter
When using a VFD
per NEMA MG-1,part
Installation
speeds. To benefit from these advantages, it is important that the drive be installed correctly
Mechanical Equipment
Installation
Operation
Fluid Cooler Start-Up
Water System
Fluid Cooler Operation
General
Operation
2.Air wet-bulbtemperature Cold process fluid temperature will also vary with the wet-bulbtemperature of the air entering the fluid cooler. Reduced wet-bulbtemperatures will result in colder process fluid tem- peratures. However, the cold process fluid temperature will not vary to the same extent as the wet-bulb.For example, a 11C reduction in wet-bulbmay result in only a 8C reduction in cold process fluid temperature
Operation
Wintertime Operation
Operation
Intermittent Wintertime Operation
Operation
ing conditions
Protection Against Coil Freezing
Operation
Water Treatment and Blowdown
Maintaining Water Quality
Operation
Fluid Cooler Cleaning
Blowdown
Operation
Operation
centrations. The following table shows the minimum amount of blowdown percent of flow required to maintain different concentrations with various cooling ranges
Bushing Fastener Torque Values
Maintenance
Fluid Cooler Maintenance
Belt Tensioning
Maintenance
protective clothing and equipment
Seasonal Shutdown Instructions
Maintenance
Prolonged Shutdown
Maintenance
ence with free rotation of the fan drive
SPX Cooling Technologies Services
Maintenance
Maintenance Schedule
Additional Services
Cause
Troubleshooting
Trouble
Remedy
Cause
Troubleshooting
Trouble
Remedy
Page
Page
Manual uk 07-1185C