Manuals
/
SPX Cooling Technologies
/
Household Appliance
/
Humidifier
SPX Cooling Technologies
none user manual
Models:
none
1
31
32
32
Download
32 pages
104 b
25
26
27
28
29
30
31
32
<
>
Troubleshooting
Install
Maintenance
Motor Wiring
Fluid Cooler Cleaning
Air wet-bulbtemperature Cold process fluid temperature will also vary with the wet-bulbtemperature of the air entering the fluid cooler. Reduced wet-bulbtemperatures will result in colder process fluid tem- peratures. However, the cold process fluid temperature will not vary to the same extent as the wet-bulb.For example, a 11C reduction in wet-bulbmay result in only a 8C reduction in cold process fluid temperature
How to
Safety
SPX Cooling Technologies Services
Page 31
Image 31
Page 30
Page 32
Page 31
Image 31
Page 30
Page 32
Contents
Marley MC Fluid Cooler
Page
Contents
Preparation
Safety First
Preparation
Fluid Cooler Location
Hoisting Fluid Cooler
Installation
Shipment
Receiving Fluid Cooler
Installation
Fluid Cooler Installation
When using a starter
Motor Wiring
Installation
per NEMA MG-1,part
When using a two-speed starter
When using a VFD
Installation
speeds. To benefit from these advantages, it is important that the drive be installed correctly
Installation
Installation
Mechanical Equipment
Fluid Cooler Start-Up
Operation
Water System
General
Fluid Cooler Operation
Operation
Operation
2.Air wet-bulbtemperature Cold process fluid temperature will also vary with the wet-bulbtemperature of the air entering the fluid cooler. Reduced wet-bulbtemperatures will result in colder process fluid tem- peratures. However, the cold process fluid temperature will not vary to the same extent as the wet-bulb.For example, a 11C reduction in wet-bulbmay result in only a 8C reduction in cold process fluid temperature
Operation
Wintertime Operation
Operation
Intermittent Wintertime Operation
ing conditions
Operation
Protection Against Coil Freezing
Maintaining Water Quality
Water Treatment and Blowdown
Operation
Blowdown
Fluid Cooler Cleaning
Operation
centrations. The following table shows the minimum amount of blowdown percent of flow required to maintain different concentrations with various cooling ranges
Operation
Belt Tensioning
Maintenance
Fluid Cooler Maintenance
Bushing Fastener Torque Values
protective clothing and equipment
Maintenance
Maintenance
Seasonal Shutdown Instructions
Maintenance
Prolonged Shutdown
ence with free rotation of the fan drive
Maintenance
SPX Cooling Technologies Services
Maintenance Schedule
Additional Services
Remedy
Troubleshooting
Trouble
Cause
Remedy
Troubleshooting
Trouble
Cause
Page
Page
Manual uk 07-1185C