Operating Instructions

Operating Instructions

S&G® Z03 D-DriveMulti-User Electronic Safe Lock

2005 Series

The S&G© X03 D-Drivelock combines ease of operation with security and flexibility. Its advanced electronic circuit design makes it easy to open and easy to change codes. Follow these instructions carefully to get the best possible use from your lock.

Introduction

This S&G© X03 D-Drivelock is shipped from the factory in multi-user mode with a factory master code of 1 2 3 4 5 6 #. This code can be used to open the lock and set or change codes. You should set the lock to your own, unique master code.

Your lock can be programmed with a management reset code that can be used to regain control of the lock in the event the master code is lost. The management reset code must be programmed into the lock before the master code is changed for the first time.

At your discretion, the lock can be set to accept a supervisor code, up to seven different user codes, and a time delay override code. The master code holder and the supervisor code holder (if a supervisor code is set) are responsible for maintaining the number of active users programmed into each lock. The master code holder and the supervisor code holder can create and delete user codes.

The master code is designated as code #0. The supervisor code (if set) is designated as code #1. The user codes (if set) are designated by user position numbers 2, 3, 4, 5, 6, 7, and 8. The time delay override code (if set) is designated as code #9.

Each time a button is pressed, the lock acknowledges it by sounding a “beep,” and the LED on the keypad will light momentarily as the “beep” sounds. If it does not, check your battery (or batteries) to make sure it is fresh and connected properly, then try again.

All codes must contain six digits or six letters. Any digit or letter can be used as many times as you wish. For instance, the following codes (while not recommended) will operate the

lock: 5 5 5 5 5 5 # OR J J J J J J #

All codes end with #. This signals the lock that you have finished entering all digits of the code.

If you pause more than 10 seconds between button presses when entering a code, the lock will assume you do not want to continue, and it will reset itself to the original code. To open the lock,

begin the code entry sequence once again from the first step.

If you realize you have pressed an incorrect button when entering a code, press or simply pause ten seconds or more, then begin entering your code again.

If five incorrect codes are entered in a row, the S&G© X03 D- Drivelock will shut down for a period of ten minutes. This is a security feature. Entering a code during this period will result in two long error tones (braps). Pressing any buttons during the lockout period will not affect the penalty timer.

After ten minutes, the lock should operate normally.

The lock can also go into the lockout period during programming if it interprets an incorrect programming sequence as five or more consecutive incorrect code entries. If the lock emits two long error tones (braps) during repeated programming attempts, it is in lockout mode. Wait ten minutes, then try again.

For UL installations, the maximum number of working codes allowed is one.

Personal data which can be directly related to a code holder, such as a birthdate, should not be used in making up a lock code. Avoid codes which can be easily guessed.

After the lock is changed to a new code, the lock function must checked by locking and unlocking it several times with the container door open. Make sure it functions correctly before closing the door.

Note: This lock has been Listed by Underwriters Laboratories for use with the following S&G keypad(s): 6130-2XX and 6130-3XX

Sargent & Greenleaf, Inc.

Sargent & Greenleaf S.A.

A Wholly Owned Subsidiary of Stanley Security Solutions, Inc.

9, chemin du Croset

PO Box 930, Nicholasville, Kentucky 40356 USA

1024 Ecublens, Switzerland

Phone (859) 885-9411

Phone +41-21 694 34 00

Phone (800) 826-7652

FAX +41-21 694 34 09

FAX (859) 887-2057

 

FAX (800) 634-4843

Document 630-735

© Copyright 2006, Sargent & Greenleaf

Revised 7/25/06

Page 1
Image 1
Stanley Black & Decker 2005 Series manual Operating Instructions, S&G Z03 D-Drive Multi-UserElectronic Safe Lock