Opening the Lock

Operating Instructions

S&G® Z03 D-DriveMulti-User Electronic Safe Lock

2005 Series

Opening the Lock

 

the time delay, for the opening code at the end of the time delay,

 

With No Time Delay

 

or for both codes. The silent alarm signal will be sent each time a

 

duress code is entered. (Note: Lock codes 4 - 8 are not available if the

A valid code is needed to open the lock. This is how to open the

 

duress feature is turned on. If time delay override is disabled or not used, lock

lock with the original factory master code of 1 2 3 4 5 6. Make

 

code 9 is available.)

sure the keypad is turned counterclockwise to stop.

 

Using a Time Delay Override Code

Enter 1 2 3 4 5 6 #

 

 

This lock is capable of using a time delay override code if it

Then, within six seconds, turn the keypad clockwise about

 

 

was originally ordered with this feature, and if the TDO (time delay

70 degrees, until it comes to a positive stop. Do not put any

 

 

override) feature is enabled. As the name implies, the time delay

pressure on the safe handle until after the keypad has been

 

 

override code can be used to open the lock without waiting for

turned. To re-lock the S&G© X03 D-Drive, turn the keypad back

 

 

the time delay period to expire. This is useful for armored car cash

counterclockwise to stop. When the mechanism re-locks, it will emit a

 

pickups. The TDO code only works when your lock uses a time delay.

double beep consisting of a low tone followed by a slightly higher tone. If

 

Your lock is capable of two different types of time delay override.

you do not hear the double beep, the mechanism is not properly locked.

 

 

Single control time delay override allows the TDO code holder to

 

 

With Time Delay Active

 

simply enter his code to open the lock. The time delay period is

 

completely bypassed. For example, if the TDO code is 9 8 7 6 5 4,

Time delay enforces a waiting period between entry of the first

 

 

it would only be necessary to press the following keypad buttons to

code and opening of the safe. This feature is a proven deterrent to

 

 

unlock the safe.

armed robbery. Any valid lock code can be used to start the time

 

 

Enter 9 8 7 6 5 4 #

delay. When this code is entered, the lock beeps three times and

 

 

The other type of time delay override is dual control TDO. To use

begins counting down the delay period. The lock will beep once

 

every ten seconds during the delay period. At the end of the delay

 

this type of time delay override, it is necessary to start the lock’s

period, the lock will beep ten times rapidly. Enter a valid code

 

time delay by entering any valid code other than the TDO code.

for the lock. After the code is entered, the lock will release for six

 

Then, within one minute, enter the TDO code. The lock will open

seconds to allow you to turn the keypad and open the safe.

 

immediately. This type of time delay override places a secondary

With Duress Active

 

control on the TDO code holder, adding a measure of extra

 

security. The following example uses the factory set master code

Duress , sometimes referred to as “silent alarm,” is a feature that

 

(1 2 3 4 5 6) to start the time delay, then a TDO code of 9 8 7 6 5

causes an alarm signal to be sent when a code is entered. This

 

4 is used to open the lock without waiting for the time delay period

capability must be enabled in the lock, and an optional duress

 

to expire.

module must be added to the lock and connected to an existing

 

Enter 1 2 3 4 5 6 #♪♪♪ 9 8 7 6 5 4 #

alarm system for this feature to work.

 

Useful Operating Information

A duress code (one which triggers the alarm signal) is simply

 

 

The lock will emit a long error tone if an incorrect or incomplete

any valid lock code with 1 added to the last digit. For instance, if

 

you create a user code of 2 2 2 2 2 2, the duress version of this

 

code is entered. If five or more incorrect codes are entered in

code is 2 2 2 2 2 3. This code is valid for operating the lock and

 

a row, the lock will go into a ten-minute lockout period. If you

simultaneously triggering the duress alarm signal.

 

attempt to enter a code during this lockout period, two long error

When the duress feature is turned on, lock codes 0, 1, 2, 3, and

 

tones will be heard. Simply wait ten minutes, then attempt to

 

operate the lock again. The lockout period cannot be bypassed. You

9 are capable of triggering the silent alarm signal. If a time delay

 

 

must wait for it to time out.

is programmed into the lock, a duress code can be used to start

 

 

 

© Copyright 2006, Sargent & Greenleaf