OPERATION
RECOMMENDED HYDRAULIC OILS Below is a list of recommended oils by brand.
Brand | Biodegradable | Description |
CITGO | No | Hydurance AW32 |
AMS Oil | No | HVH 32 |
Exxon Mobil | No | Univis HVI26* |
Exxon Mobil | No | DTE 10 Excel |
Shell | No | S2 V 32 |
Chevron | No | Rando HDZ 32 |
Conoco Phillips | No | Unax |
Clarion (CITGO) | Yes | Green Bio 32 |
Exxon Mobil | Yes | EAL 224H |
Chevron | Yes | Clarity AW32 |
Terresolve | Yes | Envirologic 132 |
Shell | Yes | Naturelle |
*Recommended for extreme cold temperatures
QUICK DISCONNECT COUPLERS
If adapter fittings are used, they must be approved steel hydraulic fittings meeting a minimum operating pressure rating of 2500 psi/172 bar. Do not use galvanized pipe fittings or black pipe fittings.
Use thread tape or pipe joint compound when installing quick disconnect couplings to hose or tool fittings. Fol- low the instructions furnished with the selected thread sealant. DO NOT OVERTIGHTEN THE FITTINGS.
OPERATING THE TOOL CIRCUIT
Facing the panel, the male quick disconnect fittings are the PRESSURE FLUID OUT fitting. The female quick disconnect fittings are the RETURN FLUID IN (RE- TURN) fitting.
PRESSURE (OUT) | RETURN (IN) |
The “Dual Circuit” control panel contains connections for two 5 GPM tool circuits. In addition, the two circuits may be combined into one 10 GPM tool circuit.
1.If using one 5 GPM tool circuit, select either the up- per or lower circuit and connect the PRESSURE
FLUID OUT hose to the male coupler and connect the RETURN FLUID IN (RETURN) to the female coupler next to it. Connect the other ends of the hoses to the tool.
If using both 5 GPM tool circuits, connect PRES- SURE FLUID OUT hoses to the male couplers and connect the RETURN FLUID IN (RETURN) hoses to the female couplers. Connect the other ends of the hoses to the tools.
NOTE:
Before starting the engine make sure the tool circuit switches are in the OFF position.
The power unit will not start if the tool selector switches are not in the OFF position.
2.Ensure the throttle control is pulled fully back to the idle position.
3.Ensure the tool circuit switches are in the OFF posi- tion.
4.Pull the choke out until it stops.
MHP3 User Manual ◄ 13