Item

Lowest

Default

Highest

Meaning

 

Value

Value

Value

 

 

 

 

 

 

Mc1 V X.XX

N/A

N/A

N/A

Display’s primary processor software version and checksum.

LOCKOUT ID

10000

12345

65535

TreadClimber® lockout ID.

MINIMUM

0.5/0.8

0.5/0.8

2.0/3.2

Minimum speed in mph (UNITS=English), or km/hr (UNITS=Metric).

SPEED

5.0/5.0

 

 

 

MAXIMUM

10.0/16.0

12.5/20.0

Maximum speed in mph (UNITS=English), or km/hr (UNITS=Metric).

SPEED

3

 

 

Caution: See Motor Calabration before making any changes.

ACCELERATI-

12

30

Time, in seconds, to reach maxmium speed from 0 mph (0 km/hr).

ON TIME

3

 

 

 

DECELERATI-

11

30

Time, in seconds, to reach 0 mph (0 km/hr) from maximum speed.

ON TIME

1.00

 

 

 

DATE

1.98

12.99

TreadClimber manufacture date.

STOP

-

-

-

Either E-Stop or Lanyard.

LAST DECK

0

0

65,535

Number of miles (UNITS=English), or km (UNITS=Metric) since the

 

0

 

 

running deck was last serviced or replaced.

LAST BELT

0

65,535

Number of miles (UNITS=English) or km (UNITS=Metric) since the

 

-

 

 

running belt was last replaced.

PROGRAM

-

-

Provides access to programs usages and counters. (See Sub Menu)

STATS

-

 

 

 

LED TEST

-

-

LED Testing function, Press OK to begin

KEYPAD

-

-

-

LED Testing function, Press OK to begin

HEART RATE

-

-

-

HEART RATE Test function.

TEST

-

 

 

 

SERIAL

-

-

RS 232 Ports test (Manufacture Test Only).

TEST

-

 

 

 

ERROR

-

-

Provides Access to Error List.

LAST ERROR

-

-

-

Last Error List Menu, Press OK to View

LIST

-

 

 

 

CALIBRATION

-

-

Provides Access to View Calibration Data.

VALUES

-

 

 

 

MOTOR

-

-

Motor Calibration Function, Press OK to begin.

CALIBRATION

-

 

 

 

TREADLE

-

-

Display current value of treadle sensor

SENSOR

-

 

 

 

BURN IN

-

-

Burn In Mode Function (Manufacture Only).

MODE

 

 

 

 

CCB V X.XX

 

 

 

 

USB V X.XX

 

 

 

 

When the MINIMUM SPEED or MAXIMUM SPEED parameters are changed, the unit will perform an auto calibration. To terminate the auto calibration and return the parameter to its default setting, press the STOP key.

TREADCLIMBER by STAR TRAC - OWNER’S MANUAL Operating Instructions 45

Page 45
Image 45
Star Trac E-TCI Lockout ID, Minimum, Maximum, Speed Accelerati, On Time Decelerati, On Time Date, Stop, Last Deck