2.4. Connecting the compressed-air supply

Check compressed-air piping for correct installa- tion and assembly.

Check fittings, length and quality of the hose con- nections for agreement with requirements.

Check all compressed-air lines for leakages.

You need a compressed-air supply with 5 - 6 bar (72.52-87.02 PSI) system overpressure. The air should be free from oil and water, if possible.

Connect the compressed-air hose, which is part of the supply, to the injector tube and to the control and maintenance unit. To this end, the com- pressed-air hose is firmly pressed into the con- necting sockets.

Connect the control and maintenance unit to the compressed-air supply (max. in- put pressure 10 bar (145.04 PSI) system overpressure).

Set the pressure on the pressure reducer at 5 - 6 bar (72.52-87.02 PSI).

F

Maximum input pressure 10 bar (145.04 PSI) (system overpressure).

Maximum output pressure 6 bar. (87.02 PSI)

SM4-610

Installation instructions 17