Filter of the electrical cabinet

STT 1600

Filter of the electrical cabinet

Remove the lid of the filter.

Remove the filter mat.

Blow through the filter mat with compressed air from inside to outside or renew the filter mat. Clean the filter housing. Use lint-free cleaning rags.

Re-install the cleaned/new filter mat.

Replace the lid of the filter.

F

Never operate the dryer without filter mat.

&

Order number filter mat:

ID 87491

 

 