Sterling Plumbing 882.00253.00 Reviewing Pump Status, Pump Status Screen During Operation

Models: 882.00253.00

1 45
Download 45 pages 62.6 Kb
Page 26
Image 26

Reviewing Pump Status

The “Pump Status” screen is the counterpart of the “Station Status” screen. To reach the “Pump Status” screen from any other screen, touch PUMP STATUS on any screen. The “Pump Status” screen appears.

Figure 10: “Pump Status” Screen During Operation

The status of each pump is color-coded. You can see an explanation of each status by using the online help. To do so from this screen, complete the following steps:

1.Touch HELP button. The “HELP Menu” screen appears.

2.Touch PUMP STATES. The “Pump Symbols Help” screen appears, explaining the status represented by each color.

3.When you are finished reviewing the information, touch HELP MENU.

The following table explains the status represented by each color at the Station Status screen.

Color

Label

Description

Gray outline

Offline

Pump is not enabled. The controller ignores any alarms.

Green

Ready

Pump is off, waiting for demand from a station.

Light Blue

Idle

Pump is on, waiting for demand from a station. If there is no

 

 

demand before the end of the auto shutdown delay, the pump

 

 

will turn off.

Blue

Convey

Pump is conveying material to a station.

Red,

Alarm

Pump is in alarm.

Red outline

Critical

Pump is in critical alarm. The controller has disabled the pump

 

 

until the alarm is cleared.

Yellow

Ramping

Pump is in process of starting or stopping.

 

Up/Down

 

Additional basic information about each pump, including configuration settings and the number of hours the pump has been running, is available at the “Pump Setup” screen. For details on configuration settings, see page 37. For details on the hour meter, see page 31.

4 –Pump 38-Station Controllers

Chapter 4: Operation

25 of 44