Chapter 6: Configurable Settings

This section describes the proper setup of the 4 pump, 38-station control system parameters. These parameters are operator changeable; however, these items should require setup only during the initial installation. Only authorized personnel should change them.

Many of the variables and setup parameters have been preset at the factory and do not need to be changed. However, this section of the manual will address all of the setup parameters that were available at the time of printing. The purpose of this is to familiarize the reader with all the setup parameters and their usage.

6-1 Options for Station Setup

Name

Description

Options

Default

Conveying Options

 

 

 

Convey time

Length of time the station’s vacuum valve remains

1–999 sec.

30 sec.

 

open to allow material to be drawn in. (For a

 

 

 

volume-fill station, the valve closes when material

 

 

 

covers the station’s volume-fill proximity sensor or

 

 

 

this time elapses, whichever comes first.)

 

 

 

Adjust this value to match the actual time needed

 

 

 

to fill the station.

 

 

(Last convey time)

Display only. Length of time the station’s vacuum

 

 

 

valve was open for receiving material during the

 

 

 

most recent convey. This information is displayed

 

for your reference when adjusting convey time and

 

 

 

dump delay.

 

 

Unload delay

Length of time allowed for material to drain from

1–99 sec.

10 sec.

 

the station into the receiver. The controller will not

 

 

 

attempt to deliver more material to the station until

 

 

 

this time has elapsed.

 

 

 

Adjust this value to match the actual time needed

 

 

 

to drain the station. If it is set too short, the

 

 

 

controller may attempt to refill the station before it

 

 

 

is empty, causing material to back up and/or

 

 

 

underusing the station’s capacity. If it is set too

 

 

 

long, the system may be unable to keep up with

 

 

 

your equipment’s demand for material.

 

 

Dry air

When this option is enabled, dry air will be used to

disabled,

disabled

 

convey material to station (Requires additional

enabled

 

 

optional equipment.)

 

 

Purge

When this option is enabled, source air is used to

disabled,

disabled

 

cleanout the stations material line after every

enabled

 

 

convey. (Requires additional optional

 

 

 

equipment.)

 

 

Purge time

Amount of time allowed to clear material line

0-999

15 sec.

Assigned to pump n

Number (address) of the pump to which this

0–4 (0 = not

0

 

station’s vacuum line is connected.

assigned)

 

4 –Pump 38-Station Controllers

Chapter 6: Configurable Settings

36 of 44

Page 37
Image 37
Sterling Plumbing 882.00253.00 specifications Configurable Settings, Options for Station Setup

882.00253.00 specifications

Sterling Plumbing has established a solid reputation in the plumbing industry, and their model 882.00253.00 is an exemplary product that showcases quality and innovation. This particular item is part of Sterling's commitment to providing reliable and stylish plumbing fixtures that meet the needs of modern homes.

One of the standout features of the Sterling Plumbing 882.00253.00 is its exceptional design. The product is crafted with sleek lines and a contemporary aesthetic, making it an ideal choice for various bathroom styles, from minimalistic to more traditional setups. The finish is not only visually appealing but also practical, as it resists tarnishing and corrosion, ensuring durability and longevity.

In addition to its attractive design, the 882.00253.00 includes advanced technologies that enhance its functionality. The model employs a user-friendly installation system, allowing for a smooth and hassle-free setup. Homeowners or contractors can easily install this fixture without the need for specialized tools, reducing labor costs and installation time.

Another key characteristic of this plumbing fixture is its water efficiency. The Sterling 882.00253.00 is engineered with advanced flow technologies that help conserve water without compromising performance. This eco-friendly feature is becoming increasingly important as more consumers look for ways to reduce their environmental footprint and lower utility bills.

The Sterling Plumbing model also boasts robust construction. Made from high-quality materials, it is designed to withstand everyday wear and tear in busy households. The sturdy components ensure a dependable performance throughout its lifespan, making it a wise investment for homeowners and builders alike.

Furthermore, the 882.00253.00 emphasizes user comfort and accessibility. The ergonomic design and intuitive controls make it easy to use for individuals of all ages, enhancing overall user satisfaction. Whether it’s for bathroom usage or other plumbing needs, this model does not fall short in delivering top-tier performance.

Overall, the Sterling Plumbing 882.00253.00 stands out as a remarkable fixture that blends aesthetic appeal with cutting-edge technologies and user-focused design. Its durability, efficiency, and modern styling make it a favorable option for consumers looking to upgrade their plumbing solutions. Investing in this model means choosing a reliable product that aligns with both functionality and contemporary design principles.