B.Freezing Cylinder
The Freezing Cylinder
NOTE
The control on the left side of the freezer also controls the refrigeration of both mix hoppers. The left Freezing Cylinder
C. Push To Freeze Switch
The PUSH TO FREEZE switch is a membrane or "snap" switch used to start the freezing cycle. During initial freeze down, the The Main Freezer Power switch and Freezing Cylinder
NOTE
After the auger drive motor starts, there is a 3 second delay before the compressor starts.
G. Amber Light
During the normal operation, the amber light next to the PUSH TO FREEZE switch will illuminate after the freezer has been idle for the preset cycles. Before drawing product, press the PUSH TO FREEZE switch. A horzontal status bar on the LCD display will begin to fill the screen as product freezes down. Wait until at least six bars are dirsplayed or the green light is illuminated before dispensing.
NOTE
If the freezer shuts off and alternating green and amber lights flash on the control panel, the freezer is running in the "cab only " mode (both freezing cylinders are turned off) or the freezer is in an error condition. Note the display on the LCD screen. If the screen displays an error, turn the Freezing Cylinder Off/On switch to the OFF position, correct the problem and place the Freezing Cylinder Off/On switch to the ON position. (Refer to Troubleshooting in Section 4).
H.Green Light
The green light is used to indicate that the product has reached the proper consistency and is ready to be dispensed. The light begins to flash at 98% of consistency.
I.Clean Switch
The CLEAN switch is a membrane, or "snap" switch. When the switch is pushed, the freezing cylinder's refrigeration system will be OFF and the auger will rotate for cleaning. The CLEAN mes- sage will display on the LCD screen. When the switch is pushed again, the auger will stop and the amber light will flash indicating the freezer is in the CLEAN mode. To exit the CLEAN mode turn the Freezing Cylinder Off/On switch to the OFF position. If the freezer is left in CLEAN for more than 30 minutes, it will go into an error mode. See Section 4 regarding errors.
J.Drive Motor Overload
The internal drive motor overload will trip if the drive motor is overloaded. It will reset after approximately
K.Mix Low Light Indicator
A MIX LOW message will appear on the LCD display to alert the operator of a low mix condition. The message will display when there is approxi- mately one gallon of mix left in the hopper. When the MIX LOW message is displayed, refill the hopper immediately.
L.Dispense Rate Adjusters
The dispense rate adjuster limits the opening of the spigot. To adjust product dispense rate, turn the adjusting knob clockwise for slower flow and counter- clockwise for faster flow. It takes at least five complete turns of the adjusting knob to make a noticable difference in the dispense rate.
M.High Head Pressure Cut Out (water cooled models only)
If the head pressure exceeds 445 PSIG (28 bar) , the high head pressure cutout will trip. The reset button can be accessed from the top left corner on the right side panel of the freezer.
N.Front Door Safety Switch
The front door safety switch prevents the auger from turning when the front door is removed. The switch is open when the door is removed and closed when the door is properly installed.
8