2.Connect free end of tubing to mix check valve. Observe direction of check valve flow arrow. Secure with hose clamp. Connect 24 inch (61cm) length of 3/8 inch (9,5mm) I.D. plastic food grade tubing to free end of check valve and secure with hose clamp.
3.Connect elbow fitting to free end of tubing. Con- nect opposite end of elbow to 1/4 inch I.D. tan tubing on the left side of pump head. Secure with hose clamps (see Figure 5 and 6).
When Using Bag Connection System (BCS) with Two Bags Per Side (optional kit #2183189):
1.Connect 3/8 inch (9,5mm) I.D. plastic food grade tubing to a bag adapter. Secure with hose clamps. This bag adapter will connect to the bag nearest the front of the freezer.
2.Slide the hose clip over free end of 3/8 inch (9,5mm) I.D. plastic food grade tubing. Attach free end of tubing to a manifold adapter. Secure with large hose clamp or equivalent. Push the manifold adapter into the left port of the mix inlet manifold and secure with retaining clip. (see Figure 9).
3.Connect 3/8 inch (9,5mm) I.D. plastic food grade tubing to a bag adapter. Secure with hose clamps. This bag adapter will connect to the bag nearest the back of the freezer.
4.Attach free end of tubing to a manifold adapter. Secure with large hose clamp or equivalent. Push the manifold adapter into the right port of the mix inlet manifold and secure with retaining clip. (see Figure 9).
5.Place two mix bags into each mix container as shown in Figure 10 (left mix container shows two bag configuration).
6.Connect the bag adapter attached to the left side of the manifold to the mix bag in the front of the mix container (nearest the cabinet door). Connect the bag adapter attached to the right side of the manifold to the mix bag in the back of the mix container (see Figure 10).
When Using Bag Connection System (BCS) with One Bag Per Side (optional kit):
1.Connect 3/8 inch (9,5mm) I.D. plastic food grade tubing to a bag adapter. Secure with hose clamps.
2.Connect free end of 3/8 inch (9,5mm) I.D. plastic food grade tubing to mix check valve. Observe direction of check valve flow arrow. Secure with hose clamp. Connect 3/8 inch (9,5mm) I.D. plas- tic food grade tubing to free end of check valve and secure with hose clamp.
3.Connect elbow fitting to free end of tubing. Con- nect opposite end of elbow to 1/4 inch I.D. tan tubing on the left side of pump head. Secure with hose clamps (see Figure 5 and 6).
4.Place one mix bag into each mix container as shown in Figure 10 (right mix container shows one bag configuration).
5.Connect the bag adapter to the mix bag. (see Figure 10).
When Using Two Mix Containers or Bag Connection Systems (BCS) on one Side (optional kit #2183189):
1.The F431 can be configured to operate with only one freezing cylinder turned on. This may be done if only one flavor is being dispensed during slow times. In this case, running only one freezing cylinder will help minimize product breakdown, while reducing mix container filling or mix bag replacement.
2.Connect two mix containers or two mix bags as described above, but connect both containers to the mix line manifold of the freezing cylinder you will be using.
6