G. Amber Light

During the normal operation, the amber light next to the PUSH TO FREEZE switch will illuminate after the freezer has been idle for the preset cycles. Before drawing product, press the PUSH TO FREEZE switch. A horzontal status bar on the LCD display will begin to fill the screen as product freezes down. Wait until at least six bars are dirsplayed or the green light is illuminated before dispensing.

NOTE

If the freezer shuts off and alternating green and amber lights flash on the control panel, the freezer is running in the "cab only " mode (both freezing cylinders are turned off) or the freezer is in an error condition. Note the display on the LCD screen. If the screen displays an error, turn the Freezing Cylinder Off/On switch to the OFF position, correct the problem and place the Freezing Cylinder Off/ On switch to the ON position. (Refer to Troubleshooting in Section 4).

H.Green Light

The green light is used to indicate that the product has reached the proper consistency and is ready to be dispensed. The light begins to flash at 98% of consistency.

I.Clean Switch

The CLEAN switch is a membrane, or "snap" switch. When the switch is pushed, the freezing cylinder's refrigeration system will be OFF and the auger will rotate for cleaning. The CLEAN mes- sage will display on the LCD screen. When the switch is pushed again, the auger will stop and the amber light will flash indicating the freezer is in the CLEAN mode. To exit the CLEAN mode turn the Freezing Cylinder Off/On switch to the OFF position. If the freezer is left in CLEAN for more than 30 minutes, it will go in error.

J.Drive Motor Overload

The internal drive motor overload will trip if the drive motor is overloaded. It will reset after approximately 10-12 minutes. If the drive motor continues to trip, refer to Troubleshooting in Section 4-.

K.Mix Low Light Indicator

A MIX LOW message will appear on the LCD display to alert the operator of a low mix condition. The message will display when there is approxi- mately one gallon of mix left in the mix container or when one bag of theBCS is empty. When the MIX LOW message is displayed, refill the container or replace the bag immediately.

L.Dispense Rate Adjusters

The dispense rate adjuster limits the opening of the spigot. To adjust product dispense rate, turn the adjusting knob clockwise for slower flow and counter- clockwise for faster flow. It takes at least five com- plete turns of the adjusting knob to make a noticable difference in the dispense rate.

M.High Head Pressure Cut Out

If the head pressure exceeds 445 PSIG (28 bar) , the high head pressure cutout will trip. The reset button can be accessed from the top left corner on the right side panel of the freezer.

N.Front Door Safety Switch

The front door safety switch prevents the auger from turning when the front door is removed. The switch is open when the door is removed and closed when the door is properly installed.

O.Menu Navigation Buttons

TheMenuNavigationButtonsallowtheusertodisplay information regarding the freezer's status of opera tion as well as adjust product consistency.

Selection Button (SEL) The SEL button is not functional in the normal operation mode. This button is only used by service technicians for freezer calibration.

Set Button (SET) Pressing this button will save a change made to the product consistency set ting. Refer to Section 4 for consistency adjust ment procedures.

Left Arrow Button (⇐) Pressing any button on the control panel will automatically illuminate the display. The backlight will turn off several seconds after use. To keep the display constantly light, press and hold the left (⇐) button for five seconds. The backlight function can be reset to normal operation in the same manner.

Up Arrow Button () Pressing this button will change the value of the product consistency. Refer to Section 4 for consistency adjustment procedures.

10