Installation | 11 |
|
|
IMPORTANT NOTE: In order to use remote ID selection from a computer or expansion chassis, the Unit ID number on the DE100 receiving frame must be set to "0" with the provided alignment tool. Refer to the section "Selecting the Unit ID Number" later in this manual for the Unit ID selection procedure.
4.With the drive carrier locked in place inside the receiving frame, install the DE100 into the 5.25” drive opening in the computer or expansion chassis. Use the appropriate guides to position the DE100, and fasten it into place with the four
(4)
Front of Unit
Mounting
Holes (Left)
Mounting
Holes (Right)
Mounting |
|
Holes (Bottom) | 0086 |
Figure 9: Receiving Frame Mounting Holes
5.Adjust the front of the receiving frame so the carrier slides freely in and out on the receiving frame guides. The position of adjoining peripheral units may require adjustment.
6.To connect the drive to a Remote Activity LED in the computer system or expansion chassis, connect the appropriate cable(s) to the receiving frame motherboard as shown in Figure 5. Connect J6 Pins 4 & 6 to a remote activity LED.
7.Connect the I/O cable from the host adapter to the receiving frame. The Pin 1 indicator on the cable must be properly aligned. Refer to Figure 5 for the correct Pin 1 location.
Make sure that only the last SCSI device is terminated. If the DE100 is at the end of a daisy chain, the terminators on the receiving frame must be enabled. If the DE100 is in the middle of a daisy chain, termination should be disabled. Refer to jumper W2 in Figure 5.
StorCase Technology, Inc. |