14 | Installation |
|
|
NOTE: The timer for device spin down is controlled by a small selector, located in a cutout on the side of the DE100 receiving frame as shown in Figure 11. When the key is turned to the OFF position, and when the timer receives a No SCSI Activity signal from the Hot Swap Board, it waits the specified delay time before displaying a “u” on the front panel of the receiving frame. The amount of time required for a disk drive to spin down is approximately 15 seconds or more. This number can vary depending on the type of SCSI device and manufacturer (e.g. a Seagate Barracuda may require 45 seconds). The factory configuration is set for 20 seconds. A different delay time may be selected with the provided aligment tool. Refer to the SCSI device manufacturer’s manual for more information on required device spin down time.
E | 0 | 2 | Spin Down/Up Time | |
|
|
| ||
C |
| 4 | 0 = 10 SECONDS | 8 = 50 SECONDS |
| 1 = 15 SECONDS | 9 = 55 SECONDS | ||
A |
| 6 | 2 = 20 SECONDS | A = 60 SECONDS |
8 | 3 = 25 SECONDS | B = 65 SECONDS | ||
|
| 4 = 30 SECONDS | C = 70 SECONDS | |
|
|
| ||
|
|
| 5 = 35 SECONDS | D = 75 SECONDS |
|
|
| 6 = 40 SECONDS | E = 80 SECONDS |
|
|
| 7 = 45 SECONDS | F = 85 SECONDS |
Front of
Receiving 0143
Frame
Figure 11: Device Spin Down/Up Timer