Page 8
Image 8
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

COVERING THE FOLLOWING MODELS:

CLARENDON – 8611LUC – P8611LUC / 8612LUC – P8612LUC

ASHDON – 8613LUC – P8613LUC / 8614LUC – P 8614LUC

Model

Gas

Gas

Working

NOX

Aeration

Injector

Gas Rate

Input kW (Gross)

Country

 

 

 

 

 

 

 

m3/h

 

 

 

 

CAT.

Type

Pressure

Class

 

 

High

Low

 

8611LUC

I2H

Natural

20 mbar

3

Ø 14.5

375

0.623

6.6

3.6

GB, IE

8612LUC

 

(G20)

 

 

 

 

 

Gross

Gross

 

P8611LUC

I3P

Propane

37 mbar

3

Ø 11.5 x 2

165

0.232

6.4

3.6

GB, IE

P8612LUC

 

(G31)

 

 

 

 

 

Gross

Gross

 

8613LUC

I2H

Natural

20mbar

3

Ø 14.5

375

0.623

6.6

3.6

GB, IE

8614LUC

 

(G20)

 

 

 

 

 

Gross

Gross

 

P8613LUC

I3P

Propane

37mbar

3

Ø 11.5 x 2

165

0.232

6.4

3.6

GB, IE

P8614LUC

 

(G31)

 

 

 

 

 

Gross

Gross

 

Efficiency Class II

Flue Outlet Size 127mm (5”) Ø

Gas Inlet Connection Size 8mm Ø

Minimum Flue Specification T260 / N2 / 0 / D / 1

Maximum Flue Temperature 180°C

Packing Checklist

Qty Description

1 Stove

1Flue Blanking plate

1Coal Retainer

1Log set (5 logs)*

2Ash Panels* (2 sections)*

1Fixing Kit Containing 1 Instruction Manual

1 Wood Screw

1 Rawplug

1 Box spanner *Packed in appliance

1

AR1618

 

A

 

B

 

C

 

D

 

E

ins

 

mm

ins

 

mm

ins

 

mm

ins

 

mm

ins

mm

253/4

 

654

253/4

 

652

163/4

 

427

181/4

 

463

5

126

8

Page 8