Stovax Electric Stove Range manual Installation Instructions, Site Requirements

Models: Electric Stove Range

1 15
Download 15 pages 33.39 Kb
Page 9
Image 9
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATIONS

These instructions cover the following models:

Manhattan Small

 

E8622 / AN / BS

Manhattan Medium

E8619 / AN / BS

Ashdon Medium

 

E8613

/ B / LG / V

Clarendon Small

 

E8517

 

 

 

Clarendon Medium

E8612

 

 

 

Clarendon Small Clear

E8517

/ B / LG

 

 

 

 

 

 

 

 

 

KEY TO SUFFIXES

 

 

 

 

 

 

Anthracite

=

AN

Midnight Blue =

 

B

 

 

 

 

 

 

 

 

Stainless Steel =

BS

Ivory

=

 

V

 

 

 

 

 

 

 

 

 

Matt Black

=

None

Laurel

=

 

LG

 

 

 

 

 

 

 

 

Clarendon Medium Clear

E8612

/ B / LG

Huntingdon

E8503

/ B / LG / V

Marlborough Small

E8560

 

Marlborough Medium

E8610

 

Stockton Small

E8573

 

Stockton 5 (Midi)

E8575

 

Stockton Medium

E8617

 

These appliances have 3 modes of operation:

a)flame effect only - with brightness and flame speed adjustment

b)flame effect + 1kw heating

c)flame effect + 2kw heating

A 230v 13amp 50Hz supply is required.

Maximum power consumption: 2064 watts.

THIS APPLIANCE MUST BE EARTHED

A 1.8 metre plug and lead are supplied

Bulb types: 2 X 40 watt ‘Elegance’ Soft E.S. (E14) candle lamp (fused)

Remote control handset battery (CR2025)

SITE REQUIREMENTS

ALL 'INGLENOOK' FIREPLACE OPENINGS:

FOR ALL MODELS, THE DIMENSIONS REQUIRED FOR AN 'INGLENOOK' TYPE OF INSTALLATION CAN BE CALCULATED BY ADDING 225 mm (9") TO THE HEIGHT AND 150 mm (6") TO EACH SIDE, ADDING 300 mm (12") TO THE APPLIANCE WIDTH. AN ADDITIONAL 50mm (2") MUST BE ADDED TO THE DEPTH DIMENSION TO PROVIDE ADEQUATE SPACE BEHIND THE APPLIANCE.

SMALL MARLBOROUGH DIMENSIONS

1

410mm

533mm

280mm

80mm

9