INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
CERAMICA MANHATTAN – 8615LUC – P8615LUC
Model | Gas | Gas | Working | NOX | Aeration | Injector | Gas Rate | Input kW (Gross) | Country | |
|
|
|
|
|
|
| m3/h |
|
|
|
| CAT. | Type | Pressure | Class |
|
| High | Low |
| |
8615LUC | I2H | Natural | 20 mbar | 3 | Ø 14.5 | 375 | 0.623 | 6.6 | 3.6 | GB, IE |
|
| (G20) |
|
|
|
|
| Gross | Gross |
|
P8615LUC | I3P | Propane | 37 mbar | 3 | Ø 11.5 x 2 | 165 | 0.232 | 6.4 | 3.6 | GB, IE |
|
| (G31) |
|
|
|
|
| Gross | Gross |
|
Efficiency Class II
Flue Outlet Size 127mm (5”) Ø
Gas Inlet Connection Size 8mm Ø
Minimum Flue Specification T260 / N2 / 0 / D / 1
Maximum Flue Temperature 180°C
Packing Checklist
Qty Description
1 Stove
1Flue Blanking plate
1Coal Retainer
1Log set (5 logs)*
1Ash Panel (2 sections)*
1Fixing Kit Containing
1Instruction Manual
1Wood Screw
1Rawplug
1Box spanner
*Packed in appliance
1
AR1620
| A |
| B |
|
| C |
| D |
|
| E | ||||
ins |
| mm | ins |
| mm | ins |
|
| mm | ins |
|
| mm | ins | mm |
28 |
| 711 | 271/ |
| 700 | 163/ | 4 |
| 427 | 177/ | 8 |
| 453 | 53/ | 145 |
|
|
| 2 |
|
|
|
|
|
|
|
| 4 |
|
8