Stovax Gazco Ceremica Log Effect Stove Range Installation Instructions, Technical Specification

Models: Gazco Ceremica Log Effect Stove Range

1 24
Download 24 pages 45.17 Kb
Page 8
Image 8
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

COVERING THE FOLLOWING MODELS:

CERAMICA MANHATTAN – 8615LUC – P8615LUC

Model

Gas

Gas

Working

NOX

Aeration

Injector

Gas Rate

Input kW (Gross)

Country

 

 

 

 

 

 

 

m3/h

 

 

 

 

CAT.

Type

Pressure

Class

 

 

High

Low

 

8615LUC

I2H

Natural

20 mbar

3

Ø 14.5

375

0.623

6.6

3.6

GB, IE

 

 

(G20)

 

 

 

 

 

Gross

Gross

 

P8615LUC

I3P

Propane

37 mbar

3

Ø 11.5 x 2

165

0.232

6.4

3.6

GB, IE

 

 

(G31)

 

 

 

 

 

Gross

Gross

 

Efficiency Class II

Flue Outlet Size 127mm (5”) Ø

Gas Inlet Connection Size 8mm Ø

Minimum Flue Specification T260 / N2 / 0 / D / 1

Maximum Flue Temperature 180°C

Packing Checklist

Qty Description

1 Stove

1Flue Blanking plate

1Coal Retainer

1Log set (5 logs)*

1Ash Panel (2 sections)*

1Fixing Kit Containing

1Instruction Manual

1Wood Screw

1Rawplug

1Box spanner

*Packed in appliance

1

AR1620

 

A

 

B

 

 

C

 

D

 

 

E

ins

 

mm

ins

 

mm

ins

 

 

mm

ins

 

 

mm

ins

mm

28

 

711

271/

 

700

163/

4

 

427

177/

8

 

453

53/

145

 

 

 

2

 

 

 

 

 

 

 

 

4

 

8

Page 8