Stovax Logic Hotbox & Convector Fire User Instructions, Oxygen Depletion Sensor, 10.‘RUNNING IN’

Models: Logic Hotbox & Convector Fire

1 24
Download 24 pages 15.94 Kb
Page 7
Image 7
PEBBLE LAYOUT - CURVED AND FLAT FRONTS

USER INSTRUCTIONS

PEBBLE LAYOUT - CURVED AND FLAT FRONTS

7.12ALL THE PEBBLES HAVE AN IDENTIFICATION ON THE UNDERSIDE. ENSURE THE PEBBLES ARE PLACED ONLY IN THEIR CORRECT POSITIONS.

7.13Place the first row of pebbles on top of the front coal resting against the frame front. All the identifications are placed face down so they cannot be seen. See diagram 13.

13

7.14Working from the outside of the appliance, place the second row of pebbles against the rear of the first row. Note the orientation of each pebble, as this is important to the performance of the fire. See diagram 14.

14

7.15Place the rear row of pebbles on top of the flame baffle, these must touch the rear panel. See diagram 15.

15

2 2 4 5

AR1173

7.16Place the remaining five pebbles between the second and rear rows. See diagram 16.

16

6

5

4

5

2

 

 

 

AR1174

 

 

 

 

 

 

 

 

 

 

 

 

 

8.OXYGEN DEPLETION SENSOR

8.1The appliance is fitted with an oxygen sensitive pilot system will act to cut off the gas supply to the fire should the oxygen in the room fall below its normal level. If the fire is turned off by this device, it usually indicates that there is a problem with the flue system, and this should be inspected by a qualified engineer. Do not attempt to use the fire until an engineer says it is safe to do so.

This device is not a substitute for an independently mounted carbon monoxide detector.

9.FLAME FAILURE DEVICE

9.1This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple.

10.‘RUNNING IN’

10.1The surface coating on the coals used in your GAZCO fire will ‘burn off’ during the first few hours of use, producing a harmless and temporary odour. This will disappear after a short period of use. If the odour persists, ask your installer for advice.

11.SERVICING

11.1This fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence, always quote the appliance type and serial number, which may be found on the databadge located on a chain beneath the control valve.

12.VENTILATION

12.1Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction.

13.INSTALLATION DETAILS

13.1To assist in any future correspondence, your installer should have completed this commissioning sheet, this records, the essential installation details of the appliance. In all correspondence always quote the Model Number and Serial Number.

7

Page 7
Image 7
Stovax Logic Hotbox & Convector Fire User Instructions, Oxygen Depletion Sensor, Flame Failure Device, 10.‘RUNNING IN’